3

Not category AP (Anesthesia Proofed) equipment.
Danger, explosion risk if used in presence of flammable anesthetics

Medical Electrical Equipment Classified with respect to electrical shock, fire and 
mechanical hazards only in accordance with UL 60601-1 and 
CAN/CSA-22.2 No. 601.1  61CB

INTRODUCTION

Caution, consult accompanying documentation for warnings and precautions.

Consult instructions for use.

1.0 INTENDED USE

The SurgiFresh® Turbo Smoke Evacuation System is intended to be used to evacuate plume / smoke 
created during electrosurgery, laser surgery, and laparoscopic or power tool surgical procedures.

Do not use the SurgiFresh® Turbo for applications other than its intended use.

Use only Surgimedics accessories with the SurgiFresh® Turbo. Using products and
accessories other than Surgimedics may void warranty.

Contact Surgimedics with questions concerning features, performance, and intended use of
this device, and to order Surgimedics accessories.

Distributed by:  Surgimedics, a division of Coastal Life Systems, Inc. 
7027 Fairgrounds Pkwy.
San Antonio, TX  78238  USA 

800-645-7418 

www.surgimedics.com

2.0 DESCRIPTION OF SYMBOLS

The following is a description of the symbols located on the SurgiFresh® Turbo.

Protective earth; protective ground.
To identify any terminal which is intended for connection to an external conductor 
for protection against electric shock in case of a fault, or the terminal of a 
protective earth (ground) electrode

Summary of Contents for SURGIFRESH TURBO

Page 1: ...s intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of suf ficient magnitude to constitute a risk of electric shock to persons This...

Page 2: ...ed area Caution Introduction of fluids into the filters could damage them and the smoke evacuation system Caution An occlusion of the smoke evacuation system can overheat the unit 2 Warning The smoke...

Page 3: ...e SurgiFresh Turbo for applications other than its intended use Use only Surgimedics accessories with the SurgiFresh Turbo Using products and accessories other than Surgimedics may void warranty Conta...

Page 4: ...d Wrap Power Switch OPERATING INSTRUCTIONS 4 FIGURE 1 Footswitch Tubing port A B Note Shown with optional handle and wheel cart 3 0 FEATURES AND CONTROLS Figure 1 User controls A Power Switch Suction...

Page 5: ...down Note Fill out the date sticker included with filter and apply it to the top of the unit The normal replacement is 90 days from the date of installation Early replacement is possible due to heavy...

Page 6: ...port of the suction canister Caution If 3 8 tubing is used avoid dislodging from the suction canister by using a sufficient length for the procedure If desired connect an optional suction wand to the...

Page 7: ...ns in Section 4 2 3 Turn on the power switch 4 The footswitch may be pressed by personnel in the operative area to start and stop the suction as needed during the procedure Place the footswitch in a c...

Page 8: ...tubing from the pre filter or suction canister 6 If a suction canister was used securely close lids caps and properly dispose canister 7 Remove the pre filter 8 Dispose of all single use waste materia...

Page 9: ...the biohazard bag provided with the new ULPA filter and prepare to dispose of the old filter 4 Grasp the used ULPA filter tabs Carefully lift the used ULPA filter out of the unit dispose of the ULPA...

Page 10: ...d pre filter 3 Replace pre filter 4 Clogged ULPA filter 4 Replace ULPA filter 5 Obstructed or malfunctioning motor and or blower 5 Refer to your Bio Engineering Dept or Surgimedics Service System does...

Page 11: ...d Safety Circuit breakers 8 amps ea Power cord 3 prong hospital grade plug Leakage Current 300 A max Power Input mains voltage nominal 120VAC Mains frequency nominal 60 Hz Mains current 6 5 amps maxim...

Page 12: ...tonio Texas Surgimedics will as an accommodation to purchaser unless otherwise directed in writing ship product to purchaser at its address freight prepaid and insured at purchasers risk and expense P...

Page 13: ...tir al usuario de la presencia de voltaje peligroso no aislado en el gabinete del producto cuya magnitud puede ser suficiente como para constituir un riesgo de descarga el ctrica para las personas Est...

Page 14: ...la posici n del extremo de entrada del tubo de succi n o su boquilla a fin de evitar lesionar al paciente o da ar de manera involuntaria material quir rgico antes de encender el sistema Advertencia El...

Page 15: ...icos en los que se emplean herramientas el ctricas No utilice el sistema SurgiFresh Turbo para otras aplicaciones no indicadas Use solamente productos y accesorios Surgimedics con el SurgiFresh Turbo...

Page 16: ...E USO 16 FIGURA 1 Puerto para interruptor de pedal A B Nota Ilustraci n mostrada con accesorios adicionales asa plegable y base con ruedas 3 0 FUNCIONES Y CONTROLES Figura 1 Controles del usuario A Bo...

Page 17: ...fecha que se incluye con el filtro y col quela en la parte superior de la unidad En general el filtro se cambia 90 d as despu s de la fecha de instalaci n Es posible que deba cambiarse el filtro ante...

Page 18: ...ucci n Precauci n Si se utiliza un tubo de 3 8 deber tener la longitud necesaria para el procedimiento a fin de evitar que se separe del recipiente de succi n Si lo desea conecte un tubo de succi n ad...

Page 19: ...enda la unidad 4 El personal que se encuentra en el sitio del procedimiento podr presionar el interruptor de pedal para iniciar y detener la succi n seg n sea necesario durante el procedimiento Coloqu...

Page 20: ...de succi n 6 Si utiliz un recipiente de succi n cierre bien las tapas y deseche el recipiente en condiciones seguras 7 Retire el prefiltro 8 Deseche todo el material quir rgico de un solo uso siguiend...

Page 21: ...na con el nuevo filtro ULPA y realice las preparaciones para desechar el filtro usado 4 Sujete las pesta as del filtro ULPA usado Lev ntelo con cuidado y s quelo de la unidad coloque el filtro en la b...

Page 22: ...tro 4 El filtro ULPA est obstruido 4 Cambie el filtro ULPA 5 El motor o el ventilador est obstruido o no funciona correctamente 5 Consulte al departamento de bioingenier a de su instituci n o al depar...

Page 23: ...e motor cerrado Seguridad Interruptor de corriente 8 amps c u Cable de alimentaci n 3 clavijas grado hospitalario Corriente residual 300 A max Alimentaci n el ctrica Voltaje de red el ctrica nominal 1...

Page 24: ...o a costa y riesgo del comprador El comprador deber 1 inspeccionar todo el embalaje para determinar si hay alg n da o externo 2 informar al transportista de la presencia de da os 3 obtener un informe...

Reviews: