SurgeX XR315 User Manual Download Page 8

 

4

 

 

Quick Start 

This section is intended to allow users with a simple straightforward system incorporating a 
single XR315 to get up and running with the minimum of effort. If this is not the case then skip 
this section and go directly to the section on detailed programming (section 5). If you are going 
to follow the quick start instructions, you only need to perform the following steps since the unit 
has been shipped with default settings suitable for basic operation. 
 
1.

 

Make all connections as per section 3. 

2.

 

Insert the screwdriver provided in the accessory kit in the hole labeled Select and turn it one 
click clockwise. Press the power button and you will see the first menu item “Unused” on the 
display. This is a function that is not available in the current software/hardware 
configuration. 

3.

 

Advance Select one click to get the second menu item “Up & Down Inputs”. Select the 
option required for the install by referring to section 3.2.1 and set the option by rotating 
Adjust. 

4.

 

If you have connected an LED to the 12V dc output for remote signaling, step through the 
menu until you reach “12V dc Output”. Then advance Adjust to select “LED”. This selection 
will make the remote LED mimic the LED on the front panel which flashes while the unit is 
powering up or powering down. 

5.

 

Turn Select fully counter-clockwise and press the power button to exit programming. Place 
two of the black plugs from the accessory kit into the adjustment holes to deter tampering 
and the unit is ready for use. 

 
Although the above steps are all that are required to get the XR315 running, you may want to 
take a look at the following programming options to see if you want to make use of any of these 
functions. You will find these listed on the reverse side of the Programming and Connection 
Guide, and they are near the end of the menu that you step through by turning Select. 
 

Low Voltage Shutdown

 

Shuts unit off if AC voltage drops below the set point 

High Voltage Shutdown 

Shuts unit off if AC voltage rises above the set point 

Power Fail Restore

 

Turns unit back on after a power failure if unit 

 

was powered up when the power failed 

 

Summary of Contents for XR315

Page 1: ...USER MANUAL SurgeX XR315 SurgeX For Surge Eliminator Residential Applications Software Version 1 0 1 1...

Page 2: ...OVER RIDE CONTROL 9 5 3 12V DC OUTPUT 10 5 4 AUXILIARY RELAY 11 5 5 FRONT PANEL PUSH BUTTON 11 5 6 OUT OF RANGE AC VOLTAGE SHUT DOWN 12 5 7 RESTORE FUNCTIONS 12 6 APPLICATIONS 12 6 1 GENERAL POINTS 12...

Page 3: ...button can be disabled if not required The LED incorporated into the button indicates the status of the unit When the LED is off the unit is fully powered down when it is on the unit is fully powered...

Page 4: ...rogrammable 12 Volt dc output can be used to control other SurgeX products Auxiliary relay or 12 Volt dc output can be programmed to provide confirmation feedback products or drive LEDs Built in AC Vo...

Page 5: ...e such as a relay or by a switch In this manual the terms momentary and latching are used when describing switches A momentary switch is considered to be a switch which provides a connection only whil...

Page 6: ...ng Note The front panel button will not operate with options a b or f 3 2 2 Over Ride Input The XR315 has the option of adding an over ride function for purposes such as providing fire safety over rid...

Page 7: ...n the XR315 is powered up and will be zero when the XR315 is powered down Program 12V dc Output for Confirm Note that the XR315 common terminal is shared between the inputs and the 12V dc output If yo...

Page 8: ...ion by rotating Adjust 4 If you have connected an LED to the 12V dc output for remote signaling step through the menu until you reach 12V dc Output Then advance Adjust to select LED This selection wil...

Page 9: ...t up turn Select counter clockwise until the display tells you to press the power button again Doing so saves the new set up information in non volatile memory and puts you back into normal operation...

Page 10: ...ution product to drive LEDs or to provide feedback to the previous XR315 in a cascaded chain Please see the applications section for full details on setting up an expanded system There are three menu...

Page 11: ...SurgeX Gang or Cascade is selected when two or more XR315s are ganged or cascaded together All these options are covered in detail in the applications section Aux Delay On Set the delay time in secon...

Page 12: ...d voltage or latching type remote control inputs Pwr Fail Restore Select Enable if you want the XR315 to power up after a power failure or out of range AC condition and the XR315 was powered up when t...

Page 13: ...ith multiple control locations they are intended primarily for a small system or for hook up to a central controller The front panel push button will not work with a latching switch contact closure or...

Page 14: ...d together This is covered in the section on cascaded systems If an over ride is required with a ganged system use the over ride input on the first XR315 If an over ride is required with a cascaded sy...

Page 15: ...ontrolled by the same inputs as a single unit system Figure 3 shows how the two units are wired together using the aux relay contacts The aux relay contacts on the XR315 terminals 6 7 are connected to...

Page 16: ...edback source and the over ride input terminal 3 is used as the feedback input Figure 6 shows how to connect and program each unit in a three unit system Note that terminals 5 and 6 are connected toge...

Page 17: ...R315 Single Unit System Controlled by Momentary Switches Location 3 Location 2 Location 1 Mixer Signal Processing Amplifier Use an LED and 1K W resistor at each location Program Up Down Inputs Momenta...

Page 18: ...4 5 6 7 XR315 Mixer Signal Processing Amplifier Single Unit System Controlled by Central Controller Program Up Down Inputs Latching Aux Output Confirm Confirmation Feedback Controller Low Voltage Cont...

Page 19: ...4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT LED and 1K 1 4W Resistor Confirmation If Required Program Up Down Inputs Momentary 12v dc Output LED Aux Output A B or C Aux Delay On Set as Needed...

Page 20: ...acles 1 2 3 4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT Confirmation If Required Program Up Down Inputs Momentary 12v dc Output A B or C 12V Delay On Set as Needed 12V Delay Off Set as Needed...

Page 21: ...1 2 3 4 5 6 7 XR315 Receptacles 1 2 3 4 5 6 7 XR315 Program Up Down Inputs One Mom 12V dc Output LED Aux Output Gang Confirmation If Required Program Up Down Inputs Latching Aux Output Gang Program Up...

Page 22: ...ired LED and 1K 1 4W Resistor Program Up Down Inputs One Mom Over Ride Input 5 30 Vdc Over Ride Func Master 12V dc Output LED Aux Output Cascade Program Up Down Inputs Latching Over Ride Input 5 30 Vd...

Page 23: ...rtain that power is being supplied to the unit consult the factory for assistance Unit will not power up from remote control connection If you have performed initial checks as above and the unit will...

Page 24: ...e you can get into the programming mode 8 Error Codes Error codes are displayed on the second line of the display Error 05 The calibration of the AC voltmeter is no longer accurate The unit is otherwi...

Page 25: ...ry B3 pulses 1 KV 500 000 3 KV 10 000 6 KV 1000 Number of Outlets 8 Remote Control Voltage 5 to 30 Volts dc Remote Control Current Draw 4 mA maximum Contact Closure Max Resistance 100 Ohms Auxiliary R...