1. Introduction 

The 24-Port 100/10M N-Way Rack-Mount Smart Switch is the latest design in its N-Way 

Switches series for easy installation and high-performance in an environment where traffic on the 
network and the number of users increase continuously. Provide 24-Port 100/10M Ethernet Switch 
support

 Auto MDI/MDI-X.

 Small businesses and corporate branch offices can take full advantage 

of 100Mbps Fast Ethernet performance and preserve existing desktop investment with no changes 
required to

 PCs, NICs, cabling,drivers, or PC configurations. 

 

1.1 Feature and Benefit 

Feature    

1. Provide 24-Port 100/10M Ethernet Switch to 

support Auto MDI/MDI-X 

2. Provide

 one fiber slide-in port

 for expansion the workgroup distance to 

2,000 meters

   

3. Provide 

back-pressure 

in half-duplex and flow control in full-duplex 

4. Store-and-forward switching scheme capability supports rate adaptation and ensures data 

integrity 

5. N-way Auto-negotiation on 

each RJ-45 port

. This allows for auto-sensing of speed   

(100/10Mbps) and auto-detecting mode

 (full-duplex or half-duplex)

 thereby providing 

    you with automatic and flexible solutions in your network connections 
6. Auto-polarity detection for correction of incorrect polarity on the received twisted-pair 
7. Data fowarding rate 

148,800 pps

 per port at 100% of wire-speed 

8. Data filtering rate eliminates all error packets, runts, etc. at 

148,800pps per port

 at 100% of wire 

speed 

9. Conform to IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX /FX, and IEEE 802.3x 
    flow control for full-duplex standards 
10. Provide 

non-blocking twenty-four ports

 full-wire speed access 

11. Support one fiber slide-in port for expansion with the 24th port 
12. Full/half-duplex mode operation on all ports 
13. Auto-negotiation capability 
14. Source address learning and aging function 
15. Provide 8K MAC address and 

2.5Mbits SSRAM buffer 

16. LEDs to indicate Power, link/activity, full-duplex/collision, and 100 status 
17. Support up to 32 VLAN groups for port pased VLAN.       

 

 
 
 
 
 

Summary of Contents for 824DXFS2B

Page 1: ...24 Port 10 100M Ethernet Rack Mount Switch With Fiber Support User Guide 482824DXFSZ1...

Page 2: ...ment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures are necessary to correct the interference WARNING Any ch...

Page 3: ...sing RRCP 14 3 3 Status 15 3 3 1 Overview 16 3 3 2 Port Status 17 3 3 3 MIB Counter 18 3 4 Configuration 20 3 4 1 Port Configuration 20 3 4 2 Cobal Configuration 23 3 4 3 Qos Configuration 24 3 4 4 VL...

Page 4: ...d ensures data integrity 5 N way Auto negotiation on each RJ 45 port This allows for auto sensing of speed 100 10Mbps and auto detecting mode full duplex or half duplex thereby providing you with auto...

Page 5: ...all error packets will be filtered and maintain maximum data integrity even under heavy loading Upgrade Designed for plug and play the Switch is fully compatible with existing Ethernet networks thus...

Page 6: ...TP Cat 3 4 5 Max cable length 100m UTP Cat 5 Max cable length 100m Multi mode Fiber cable Max cable length 2000m No of Ports 24 100 10Mbps RJ 45 ports Media Interface Exchange 24 RJ 45 ports support A...

Page 7: ...ard provides for integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber thin coax and twisted pair cable Fast Ethernet A 100 M...

Page 8: ...s Ethernet frame tags which carry VLAN information It allows switches to assign endstations to different virtual LANs and defines a standard way for VLANs to communicate across switched networks IEEE...

Page 9: ...identify IP Multicast group members Internet Group Management Protocol IGMP A protocol through which hosts can register with their local router for multicast services If there is more than one multic...

Page 10: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24 10 100Mbps RJ 45 Ports Uses these twenty four ports to connect to another Switches or Hubs Each portuses auto negotiation for automatic speed and mo...

Page 11: ...tached device Flashing Blinks to indicate that the router is actively sending or receiving data over that port FDX COL Green On Lights to indicate that the connected port is under Full Duplex mode Off...

Page 12: ...on port on the Switch to a PC via twisted pair cable with RJ 45 plugs at both ends Use Category 3 4 or 5 cable for standard 10Mbps Ethernet connections or Category 5 cable for 100Mbps Fast Ethernet co...

Page 13: ...SE T Hub The Link Act LED will light The FDX Col LED will be unlighted The 100 LED will be unlighted 100BASE TX Hub The Link Act LED will light The FDX Col LED will be unlighted The 100 will light Whe...

Page 14: ...alled and CD ROM Drive 2 This CD ROM with RRCP program 3 Your Windows CD if your computer is running Windows 98 XP 2000 NT4 0 Service Pack 6 or ME 4 UTP network cable with RJ 45 connector 3 1 Software...

Page 15: ...program the following screen will be shown up The Management Application shows one switch s information at one time You can select a switch using the pull down menu Select Switch Mac which displayed s...

Page 16: ...by double click the item in the list box Network topology link vector Show the link status of the switches Update button You can click it to get the latest information of the connected switches on th...

Page 17: ...17 3 3 2 Port Status Select the Port Status sheet You can check each port s link status and configration information in this sheet Click Refresh to get the latest information...

Page 18: ...rror count and Collision count Byte Count button Showing the each port s amounts of bytes are sent and received Packet Count button Showing the each port s amounts of packets are sent and received Ban...

Page 19: ...k Clear Counter to clear all MIB counters it will reset the counters to zero Polling Interval You can set the time period to count by click Polling Interval The Maximum Time setting is 1410065407 seco...

Page 20: ...ol trunk setting Note There will not have port G1 and G2 if you use 24 Port 10 100M Ethernet Rack Mount Switch With Fiber Support Click Config button to change the settings Select ports to config Mark...

Page 21: ...ps and Half duplex 10Mbps and Full duplex 100Mbps and Half duplex 100Mbps and Full duplex Note The default setting is Auto Negotiation That means the switch will auto select its Optimum operational mo...

Page 22: ...22 Enable Trunking Mark the items which you want to set port trunks Note There will not have port G1 and G2 if you use 24 Port 10 100M Ethernet Rack Mount Switch With Fiber Support...

Page 23: ...Press the Refresh button to read the status of the registers Press the Update button to set the registers as shown in this frame Half duplex back pressure flow control Mark Enable Disable to enable di...

Page 24: ...an recognize TCP IP Differentiated Services Codepoint DSCP priority information from the DS field defined in RFC2474 The DS field byte for IPv4 is the Type of Service TOS octet and for IPv6 it is the...

Page 25: ...an automatically turn off 802 3x flow control and Back pressure flow control for 1 2 seconds whenever the port receives a high priority frames The flow control is re enabled when no priority frames ar...

Page 26: ...Port based and Tag based VLANs Press the Refresh button to read the status of the registers Press the Add VLAN Edit VLAN Delete VLAN button and select one VLAN in the list box or double click the VLAN...

Page 27: ...VLAN tag from all tagged frame 2 Insert priority tag into the untagged high priority frame Set priority field 7 VID field 0 for high priority frame 3 Insert priority tag into the all untagged frame S...

Page 28: ...te button to set the registers and it will set all VLAN control registers to the selection VLAN Function Mark Enable Disable to enable disable VLAN function Unicast Packet Inter VLAN Leaky A received...

Page 29: ...oup member set and the VLAN member set domain limitation will be ignored 802 1Q VLAN Tag aware This function is to enable disable 802 1Q VLAN Tag aware Ingress Rule for acceptable frame types control...

Page 30: ...egister and IP Multicast Router Port Discovery register Router port report will show the IP multicast Router port list Press the Refresh button to read the register Press the Update button to set the...

Page 31: ...key of the switch and the RRCP Management Security Mask Configuration The authentication key is readable You can press the Refresh button to read the register and press the Update button to set the re...

Page 32: ...6 1 Fault Information This page shows some information likes Trunk Port Fault Network Loop Fault Test Note There will be no GigaPHY 1 2 information if you use 24 Port 10 100M Ethernet Rack Mount Switc...

Page 33: ...ill be kept All the current user configured values of internal registers will be kept The EEPROM download will NOT be done again But the system will restart the process of Auto Negotiation Note The ha...

Page 34: ...34 3 6 3 Script This page is for system manufacture using only...

Page 35: ...he Browser click System Save Configuration To load a file In the Browser click System Load Configuration And in the Open File dialog box select a rrcp file and click Load In the Setting Active Switch...

Page 36: ...nter Polling Select Option Counter Polling to set the time interval Authentication Key System will automatically generate the authentication key The authentication key can not be changed manually Auto...

Page 37: ...37 3 7 3 Help About RRCP You can check the RRCP software s version here...