8
LIGHTING INSTRUCTIONS FOR REMOTE CONTROLLED SYSTEM
Model SCVFMR
Lighting Set from Burner System
1.
Stop!!
Read the safety instructions on the previous page
before proceeding.
2. Press the on/off button to bleed the pilot system, after a
few seconds you will hear a clicking noise as the pilot
lights. (See Fig. 10)
3. If the pilot does not light, wait 30 seconds and press the
on/off button, you will hear a click, then press again to
light the pilot, continue repeating this process until the
pilot system lights.
4. It may take several attempts and up to 5 minutes to light
the pilot the first time since there will be air in the gas
line.
5. Wait fifteen (15) seconds after pilot is lit before adjusting
the flame height.
6. To increase the flame height push the up arrow on the
touch pad, until desired flame height is reached. (See
Fig. 11)
Note:
Burner has 4 different settings:
1. Pilot
2. Low flame
3. Medium flame
4. High flame
7. To decrease flame height, push the down arrow on
the touch pad, until desired flame height is reached.
(See Fig. 12)
8. To turn the burner off, press the down arrow button.
(See Fig. 12)
9. If you wish to turn off the pilot light, push the on/off button.
(See Fig. 10)
Fig. 10
Fig. 11
Fig. 12
On/Off
Button
Up
Arrow
Down
Arrow
Summary of Contents for SCVFMR 21