background image

14

Please photocopy and return registration along with proof of purchase 

within 14 days of purchase to:

Sure Heat Mfg. 

3130 Moon Station Road

Kennesaw, GA 30144

Attention: Warranty Registration

If you have other questions, please contact our Customer Service Hotline

(800) 229-5647

8/07

RMH-130-00623

LIMITED LIFETIME WARRANTY

Limited Lifetime Warranty shall apply to the original purchaser at the original installation point only

All logs are guaranteed for the lifetime of the original purchaser against destruction by fire or heat.

The burner assembly system is guaranteed for a period of three (3) years from the date of purchase and will be

repaired or replaced for freight costs only.  Valves, thermocouples, and ODS pilot assemblies are warranted for a

period of one year.

General Warranty:

This warranty does not apply in the case of improper installation, neglect, accident, misuse or

as a result of modifications of the original product.

All costs for removal and reinstallation are the expressed responsibility of the purchaser.

For repair or replacement of a defective part or parts, contact our customer service department at 1-800-229-5647.

You will be asked to provide valid warranty registration, proof of purchase and model number.

It is agreed that any repair or replacement is the exclusive remedy from Sure Heat Manufacturing. In no case shall

Sure Heat be liable for any consequential damage for breach of this or any other warranty expressed or implied

whatsoever. This limitation as to consequential damages shall not apply in states where prohibited.

Purchased From: ______________________________________________Date: __________________________

Size:

o

18”

o

24”/21”

o

30”   Model:

Name ______________________________________Date:____________Phone (        ) __________________
Address ____________________________________________________________________________________
City  ________________________________________State ____________Zip __________________________
E-mail______________________________________________________________________________________

Summary of Contents for SCVFMR 21

Page 1: ... IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas suppliers instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This...

Page 2: ...ng guide and BTU information BTU Information Set Opening Front Rear Fireplace Natural Gas L P Gas Size Height Width Width Depth Max Min Max Min 18 18 22 18 12 34 000 22 000 34 000 22 000 24 21 18 28 23 15 39 000 22 000 39 000 22 000 30 18 34 25 15 39 000 22 000 39 000 22 000 This appliance is designed as an unvented room heater when installed in a non combustible fireplace with the flue damper clo...

Page 3: ...r must be in place when the appliance is operating unless other provisions for combustion air are provided IMPORTANT During the manufacturing process this appliance is treated with certain coloring agents These agents are not harmful but may produce annoying smoke and smell as they are burned off This is a temporary occurrence that ceases after 10 hours of use During the burning off period provide...

Page 4: ...during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG Pressures in excess of 1 2 PSIG will cause damage to the unit FIREPLACE CLEARANCES To guarantee safe installation into a non combustible fireplace certain space requirements must be fulfilled 1 The clearance from the side of the unit to any combustible wall should not be less than 15 1 2 in...

Page 5: ...solution for leaks Bubbles indicate a leak Repair any leaks and recheck before proceeding DANGER DO NOT USE OPEN FLAME TO TEST FOR LEAKS 2 We suggest you do a test lighting of the burner assembly before you begin log placement Be sure to review all safety precautions in the owner s manual before you light your set 3 Press the on off button to bleed the pilot system after a few seconds you will hea...

Page 6: ... placement can lead to the production of harmful carbon monoxide while the unit is in operation Be sure that the logs are correctly placed in the notches provided for them There should be no direct impingement of flames on any of the logs WARNING Failure to position the parts specifically approved with this heater may result in property damage or personal injury DECORATIVE STONE The decorative sto...

Page 7: ...not use any telephone in your building Immediately call your gas supplier from a neighbors telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier C Use only your hand to push the touch button controls Never use tools If the touch buttons wi...

Page 8: ... may take several attempts and up to 5 minutes to light the pilot the first time since there will be air in the gas line 5 Wait fifteen 15 seconds after pilot is lit before adjusting the flame height 6 To increase the flame height push the up arrow on the touch pad until desired flame height is reached See Fig 11 Note Burner has 4 different settings 1 Pilot 2 Low flame 3 Medium flame 4 High flame ...

Page 9: ...pears while the hand held unit is learning the code See Fig 13 Remote will return to the off position MANUAL MODE 3 To light the pilot press the following buttons See Fig 14 On Off button ON will start blinking Set button while ON is still blinking This turns the unit on in manual mode hand should appear See Fig 14 4 To adjust the flame height in manual mode press See Fig 15 Up button Each press r...

Page 10: ...ure will start blinking each press lowers the temperature one degree Set button while temperature is still blinking The number of flames automatically adjusts to the correct setting in order to reach the desired temperature Note After a few seconds the display returns to showing the current room temperature 8 To turn the unit off press the following buttons See Fig 18 On Off button OFF will start ...

Page 11: ...id fuel 6 Use pipe dope on threaded joints of gas piping that is resistant to the action of LP gas 7 Install a manual shut off valve union and 1 8 NPT plugged pressure tap ahead of controls 8 Use soap and water solution when checking for leaks 9 Keep the area around the appliance clear and free of combustible materials gasoline and any flammable or explosive material 10 Follow the lighting and ope...

Page 12: ...with headache dizziness and or nausea If you experience any of these symptoms appliance may not be working properly Get fresh air at once Have appliance serviced by a qualified service technician Some individuals pregnant woman persons with heart or lung disorders anemia those under the influence of alcohol or those at high altitudes are more likely to be affected by carbon monoxide than others Du...

Page 13: ... open gas supply valve fully gas line obstruction burner inspection for tube kinks or obstructions inspect burner for dust or debris inspect supply lines for tube kinks or obstructions PARTS LIST Ref Part Name SCVFMR 18 24 21 30 Qty 1 Battery compartment 1 2 Control module 1 3 Touch button controls 1 4 Main regulator 1 5 ODS pilot system 1 6 Burner 1 7 Decorative stone shelf 1 8 Remote control han...

Page 14: ...nal product All costs for removal and reinstallation are the expressed responsibility of the purchaser For repair or replacement of a defective part or parts contact our customer service department at 1 800 229 5647 You will be asked to provide valid warranty registration proof of purchase and model number It is agreed that any repair or replacement is the exclusive remedy from Sure Heat Manufactu...

Page 15: ...15 N NO OT TE ES S ...

Reviews: