Sure Flame ID 100 Instruction Manual Download Page 3

 

EN

 

IMPORTANT 

Before using the space heater, carefully read all of the instructions and follow them precisely. 

The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of 

the equipment. 

This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on 

with the unit in the event of a change of ownership.

 

 

GENERAL RECOMMENDATIONS 

This heater runs on heating oil #2 (diesel). It is fitted with a flue 

to discharge any fumes through the chimney. 

Always follow local ordinances and codes when using this 

heater: 

•  Follow the instructions in this booklet very carefully; 

•  THE INSTALLATION OF THE UNIT  SHALL BE IN 

ACCORDANCE  WITH THE REGULATIONS OF THE 

AUTHORITIES HAVING JURISDICTION.  Also, as a 

recommended installation practice reference should be made 

to the current issue of CSA B139, Installation  Code for Oil 

Burning Equipment in Canada and NFPA 31 Standard for the 

Installation of Oil-Burning Equipment in the USA; 

•  Use only in places free of flammable vapours or high dust 

content; 

•  Never use heater in immediate proximity of flammable 

materials (the minimum distance must be 2 m); 

•  Make sure fire fighting equipment is readily available; 

•  Ensure that the machine resting surface or ground is not made 

of flammable material; 

•  Make sure sufficient fresh outside air is provided according to 

the heater requirements; 

•  An opening of roughly  one square foot  is required  for each 

gallon (US) per hour that the heater consumes; 

•  the indirect combustion heater is installed near a chimney to 

take away the fumes (see the paragraph “CHIMNEY LAY-OUT 

RECOMMENDATION”) and connected to an electrical 

switchboard; 

•  Never block air inlet (rear) or air outlet (front); 

•  In case of very low temperatures add kerosene to the heating 

oil; 

•  Make sure heater is always under surveillance and keep 

children and animals away from it; 

•  Before starting the heater always check free rotation of 

ventilator; 

•  Unplug heater when not in use. 

 

SAFETY DEVICES 

The heater is fitted with an electronic device that controls the 

flame and the maximum safe temperature by means of a 

photocell, an overheat thermostat and  an air pressure switch. 

The  electronic device controls start/stop times and trips the 

safety in case of malfunctions. It has reset button (13) that can 

assume different colours (Function Light) depending on the 

function mode: 

•  off: heater is in stand-by, waiting for heating call ; 

•  steady green: heater functioning normally; 

•  steady red: heater in safety stop; 

To restart heating after a safety stop, push reset button (13) 

for 3 seconds. 

 

Warning 

NEVER do more than two restarts in a row: 

uncombusted diesel fuel may accumulate in the 

combustion chamber and suddenly flare up at the 

next restart. 

If the safety stop persists, you have to find and eliminate the 

cause of the stop before you restart the heater.  

 

 

 

Warning 

See “TROUBLESHOOTING” to identify the cause of 

the malfunction. 

 

 

OPERATION 

Before switching on the heater and, therefore, before plugging 

it into the electrical power supply, check that the power supply 

specifications are the same as those stated on the identification 

plate. 

 

Warning  

To operate the machine, must install  the air 

dispersion cone (18) on the front of the machine as 

shown in the figure above (“Operating diagram”). 

 

 

Warning 

•  The power line must be grounded and fitted with 

a residual current circuit breaker. 

•  The heater plug must be inserted into a socket 

equipped with a mains switch. 

 

The heater must be placed on a flat, stable, and level surface 

in order to prevent it from overturning and/or diesel leaks from 

the tank filler cap. 

You can run the heater in manual by setting switch (14) to ON. 

The heater can only work automatically when a control device, 

such as a thermostat or a timer, is connected to the heater. 

Connection to the heater is made by removing the socket 

cover (15) and inserting the thermostat plug. 

To start the machine you must: 
• if connected to the thermostat, turn the switch to (ON +  ); 

• if not connected to the thermostat, turn the switch to (ON); 

When unit is started for the first time or is started after the oil 

tank has been totally emptied, the diesel flow to the burner may 

be impaired by air in the circuit. In this case the control box will 

cut out the heater and it might be necessary to renew the starting 

procedure once by depressing the reset button (13). 

If the heater does not function, the first things to do are: 

1. Check that the tank still contains some diesel; 

2. Push reset button (13); 

3. If the heater still does not function, see 

TROUBLESHOOTING” to identify the cause of the 

malfunction. 

 

Warning 

Never stop the machine by unplugging the 

electrical plug: this could cause overheating. 

 

 

STOPPING THE HEATER 

Set main switch (14) on “0” position or turn thermostat or other 

control device on lowest setting. 

The flame goes out and the fan continues to work for 

approximately 90 sec. cooling the combustion chamber. 

 

TRANSPORT

 

Warning 

Summary of Contents for ID 100

Page 1: ...CONSTRUCTION HEATERS GENERATEURS D AIR CHAUD L L 103 02 SU ID 100 ID 200 ID 300 INSTRUCTION MANUAL LIVRET D ENTRETIEN...

Page 2: ...FUEL TANK R SERVOIR COMBUSTIBLE 13 RESET BUTTON OF THE ELECTRONIC EQUIPMENT BOUTON DE REARMEMENT DE L APPAREILLAGE 14 MAIN SWITCH INTERRUPTEUR MARCHE ARRETE 15 ROOM THERMOSTAT PLUG PRISE THERMOSTAT D...

Page 3: ...ding on the function mode off heater is in stand by waiting for heating call steady green heater functioning normally steady red heater in safety stop To restart heating after a safety stop push reset...

Page 4: ...similar equipment In this case make sure that the ropes and or chains are securely attached and that they are in perfect condition before you start to move the heater MAINTENANCE To ensure correct he...

Page 5: ...efective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump plastic coupling Check fuel line system including fuel filt...

Page 6: ...t d une cellule photo lectrique de contr le de la flamme d un thermostat de surchauffe pour le contr le de la temp rature maximale et d un pressostat de l air Le bo tier lectronique g re les temps de...

Page 7: ...ionnement de la machine Le g n rateur peut tre fourni en version mobile muni de roues ou en version suspendue mont sur une structure de support avec des ancrages pour le fixage qui doit tre effectu av...

Page 8: ...mplacer Le fuel n arrive pas au br leur ou arrive en quantit insuffisante Contr ler l efficacit du raccord moto pompe Contr ler qu il n y ait pas d infiltrations d air dans le circuit du fuel en v rif...

Page 9: ...MOIN D ALIMENTATION LI1 OVERHEAT THERMOSTAT THERMOSTAT DE SURCHAUFFE EV1 SOLENOID VALVE I Stage ELECTROVANNE I Stade CO CAPACITOR CONDENSATEUR MV FAN MOTOR MOTEUR DU VENTILATEUR FUA FUSE 6 3 A FUSIBLE...

Page 10: ...THERMOSTAT DE SURCHAUFFE EV1 SOLENOID VALVE I Stage ELECTROVANNE I Stade CO CAPACITOR CONDENSATEUR MV FAN MOTOR MOTEUR DU VENTILATEUR FUA FUSE 6 3 A FUSIBLE 6 3 A RV CONTROL SWITCH COMMUTATEUR PA AIR...

Page 11: ...eiling 2 m Floor combustible LEGENDE A Minimum 1 m B Minimum 1 m C Le plus court possible D Egal superieur au diam tre de la chemin e du g n rateur E Minimum 1 m 1 Accessoire anti refoulement 2 Passag...

Page 12: ...ique W 440 785 1 330 A 4 05 7 65 11 80 Nozzle Gicleur USgal h 0 55 80 W 1 10 80 W 1 50 80 W Pump pressure Pression pompe psi 196 174 174 Static pressure Pression statique in WC 0 5 0 5 0 5 Adjustment...

Reviews: