26
7.12 Silent Knight FSK1, FSK2
7.12.1Silent Knight FSK1 Protocol
ERRLssssAAAAAAXXssss[DC4]
Where:
E
FSK protocol identifier
RR
Receiver number
L
Line number
s
Spaces
AAAAAA
Account number (if the account is 4 or 5
digits, the leading “A”s will be replaced by
spaces)
XX
Alarm code
Possible alarm codes are as follows:
00
Alarm Panic
01-08
Alarm 01-08
09
Holdup
10-19
Alarm 10-19
30
Test code
31
Trouble line 1
32
Trouble line 2
33
Expand trouble
34
Forced access
35
Restore line 1
36
Restore line 2
37
Expand restore
38
Cancel code
39
Data lost
40
Closing
41-49
Closing 1-9
50-59
Bypass 10-19
60
Trouble AC
61-68
Trouble 1-8
69
Trouble bat
70
Restore AC
71-78
Restore 1-8
79
Restore bat
80
Access
81-89
Access 1-9
90
Opening
91-99
Opening 1-9
[DC4]
Represents the terminator
Example
Printer: L1-1234-03-LIBRARY WORD
HH:MM:SS-DD/MM
Computer: E01001 123403 [14]
7.13 Silent Knight FSK2 Protocol
The DRL2E will provide two possible outputs to the
computer, according to the value set under option A7.
When the option is programmed as “02”, the com-
puter output will be as follows:
FRRLssssAAAAAAYYZZss[DC4]
Where:
F
FSK2 protocol 1 identifier
RR
Receiver number
L
Line number
s
Spaces
AAAAAA
Account number (if the account is 4 or 5
digits, the leading “A”s will be replaced by
spaces)
YY
Event code
ZZ
Zone/user number
[DC4]
Represents the terminator
Possible events are as follows:
YT00
Battery Trouble
YR00
Battery Restore
AT00
System Trouble AC
DOZZ
Access left open ID ZZ
DFZZ
Access forced ID ZZ
DSZZ
Access Station ID ZZ
AJ00
System Restore AC
LT0Z
Trouble phone line #0Z
Restore phone line 0Z
Expand trouble device ID z
Expand restore device ID z
ETZZ
Expand trouble station ID ZZ (ZZ=17-31)
ERZZ
Expand restore station ID ZZ (ZZ=17-31)
RP00
Automatic test
RXZZ
Manual test zone ZZ
CA
Automatic closing
OA
Automatic opening
CLZZ
Normal closing ID ZZ
OPZZ
Normal opening ID ZZ
CFZZ
Forced closing ID ZZ
ORZZ
Forced opening ID ZZ
Supervised closing ID ZZ
OTZZ
Supervised opening ZZ
CG0a
Closing area 0a
OG0a
Opening area 0a
DRZZ
Access granted ID ZZ
When the option is programmed as “01”, the com-
puter output will be as follows:
CRRLssssAAAAAAXYZZss[DC4]
Where:
C
FSK2 protocol 2 identifier
RR
Receiver number
L
Line number
s
Spaces
AAAAAA
Account number (if the account is 4 or 5
digits, the leading “A”s will be replaced by
spaces)
X
Event code
Y
Condition code
ZZ
Zone/user number
[DC4]
Represents the terminator
Possible events are as follows:
B600
Battery Trouble
BE00
Battery Restore
C600
System Trouble AC
CE00
System Restore AC
D60z
Trouble phone line #0z
DE0z
Restore phone line 0z
E60z
Expand trouble device ID z
EE0z
Expand restore device ID z
Summary of Contents for MLR2E
Page 2: ......