background image

 

 

 

 

 

Printed in Canada

 

Printed on 100% recycled paper

 

 

2016-07-14

 

 

 

X40234 Rev. D

 

Models

:

 

 

SUPXX-M240V12

 

SUPXX-M240V20

 

MODULATING

 

(ECM MOTOR)

 

Manufactured by: 

 

Dettson Industries inc.

 

Sherbrooke, Quebec - Canada

 

 

Caution: Do not tamper with the unit 
or  its  controls.  Call  a  qualified 
service technician.
 

INSTALLER / SERVICE TECHNICIAN:

 

USE  THE  INFORMATION  IN  THIS  MANUAL  FOR  THE  INSTALLATION  AND 
SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT 
FOR FUTURE REFERENCE.
 

HOMEOWNER:

 

PLEASE  KEEP  THIS  MANUAL  NEAR  THE  FURNACE  FOR  FUTURE 
REFERENCE.
 

IMPORTANT

:  The  furnace  must  be  installed  with  the  Modulating  Touch-

Screen  Thermostat  R02P030  (#1F95M).  If  the  furnace  is  to  be  installed with 
the modulating cooling option, use the Communicating Thermostat R02P029. 
(#1F991292)

 

 

Summary of Contents for SUPXX-M240V12

Page 1: ...echnician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KE...

Page 2: ...7 3 2 3 DELAYS Menu 7 3 2 4 SYSTEM Menu 7 3 2 5 AUTO BACKUP Menu 7 4 OPERATION 9 4 1 START UP 9 4 2 OPERATING SEQUENCE 9 4 2 1 Continuous fan 9 4 2 2 Cooling mode single stage 9 4 2 3 Cooling mode two...

Page 3: ...plain to you the following items i The main disconnect switch or circuit breaker ii The air filter and how to change it check monthly and clean or replace if necessary f Before calling for service be...

Page 4: ...he supply duct shall be installed on the top of the unit Care should be taken not to damage the wires inside while cutting the opening Install the filter rack that is supplied with the unit It is also...

Page 5: ...lower Move all wires from the two pole terminal to the three pole terminal following the corresponding colors as shown in Figure 4 The breaker and the supply conductors must be sized by adding the amp...

Page 6: ...quired that prevents the operation of the electric elements and the heat pump at the same time Refer to the instructions provided with the thermostat or the Fossil Fuel kit for the proper wiring of th...

Page 7: ...CIENT CFM TON This parameter allows to modify the CFM per TON with more precision DEHUM ON STATE This parameter defines if the dehumidification will be active high or active low DEHUM RATIO This param...

Page 8: ...DELTA T BACK COOLING HP DEHUM RATIO AC Y1 RATIO BACK SYSTEM RATIO MAX PWR FURNACE MODEL RESET SYSTEM BACK COOLING HP AC HP TONS AC COMFORT EFF CFM TON DEHUM ON STATE INSTALLER AUTO BACKUP BACK TROUBLE...

Page 9: ...varies between 5 and 100 The heating unit will apply this power ratio to the maximum available power The electrical elements will modulate to the required power and the fan will adjust itself automati...

Page 10: ...the obstruction and the elements should restart after a few minutes 5 MAINTENANCE WARNING ELECTRICAL SHOCK HAZARD Turn OFF power to the furnace before any disassembly or servicing Failure to do so ca...

Page 11: ...ler name and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total...

Page 12: ...2 7 2 3 2 7 2 3 2 7 2 3 2 7 5 2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 8...

Page 13: ...13 Figure 10 Furnace dimensions...

Page 14: ...14 Figure 11 Electrical diagram Modulating ECM SUPREME...

Page 15: ...15 Figure 12 Exploded view Modulating SUPREME...

Page 16: ...30kw 1hp ECM 30 B03811 27 Motor ass y ECM 1 2 hp prog Supreme 10 25kw 1 2hp ECM 31 B03813 18 Motor ass y ECM 1 hp prog Supreme 20 30kw 1hp ECM 32 B04415 Electronic blower kit Supreme 10 33 B04414 Elec...