Supreme
Heating User Guide
________________________________________________________________________________________________________________________________________________________________________________________________
13
1) Manual Mode
MANUAL PUMP MODE
UP=ON DOWN=OFF
MANUAL MODE allows you to manually set the aux pump to ‘on’ by pressing the UP button or ‘off’ by
pressing the DOWN button.
Pressing ENTER will return you to the SETTINGS MENU. You can also keep pressing ENTER to toggle the
filter pump from ‘on’ to ‘off’ and vice versa.
MANUAL MODE will time out, after 24 hours the controller will return to normal operation.
2) Filter Timer
SINGLE CYCLE
DUAL CYCLE
Single cycle sub menu
SINGLE CYCLE
SINGLE CYCLE
START TIME X:XX
END TIME X:XX
Dual cycle sub menus
FIRST CYCLE
FIRST CYCLE
SECOND CYCLE SECOND CYCLE
START TIME X:XX
END TIME X:XX
START TIME X:XX
END TIME X:XX
When you enter the FILTER SETUP menu you will need to select SINGLE CYCLE or DUAL CYCLE, the
selected option will be flashing, you can use the UP/DOWN buttons to change to the selected option,
once you select the required cycle by pressing SELECT you will be prompted to set the cycle START TIME
and END TIME, modify these by pressing the UP/DOWN buttons, press SELECT to accept the setting.
SINGLE CYCLE will run the filter pump once per day.
DUAL CYCLE will run the filter pump twice per day.
Factory Default is ON, DUAL CYCLE from 09:00 to 13:00 and 16:00 to 20:00.
Note that the maximum combined rated current is 10 Amps (2400W at 240VAC.)