background image

Heatseeker UniPanel®

 

Solar Pool Heating

20

Warranty Agreement

Definitions

 All capitalised expressions used in this warranty are 

defined in paragraph 17.

Warranty

 Supreme Solar Pty Ltd warrants that its services in 

installing the Product will be carried out with due 

care and skill and subject to clauses 3, 4, 5 and 6, 

that the installed Product will be free from defects in 

workmanship for a period of twenty four (24) months 

after installation (warranty includes in field labour 

costs.) The warranty is given subject to the terms of this 

warranty agreement.

The Solar Collector included in the Product carries:

 

(a)    in the case of a Strip Collector, a ten (10) year 

limited warranty from Procom Plastics Extrusions 

Pty Ltd, 38 McGregors Drive, Keilor Park, Victoria, 

3042 (Phone: (03) 9331 7589,  

Email: [email protected]); or  

 

(b)   in the case of an Evacuated Tube Collector, a ten 

(10) year limited warranty from Supreme Solar Pty 

Ltd, 2/19 Enterprise Drive, Bundoora, Victoria, 3083 

(Phone: (03) 9460 4200,  

Email: [email protected]); or

 

(c)   in the case of an UniPanel® Collector, a ten (10) year 

limited warranty from Supreme Solar Pty Ltd, 2/19 

Enterprise Drive, Bundoora, Victoria, 3083 (Phone: 

(03) 9460 4200,  

Email: [email protected]);

 

 

 For the purpose of this warranty, impact of hail is 

defined as penetration of hail stones completely 

through the panel or cracks or splits of the panel 

around the point of impact. This warranty applies in 

the case of hail measuring up to 25cm diameter in 

size, as per AS2712.

Any labour, travel and freight costs incurred are excluded from 

this warranty. Such costs are to be paid by the original purchaser.
and is the only warranty given in respect of that part of the 

Product.

 The Automatic Controller included in the Product 

carries:

 

(a)   in the case of an Aqua-Gen 3D Automatic 

Controller, a one (1) year limited warranty from 

Space Age Electronics Pty Ltd, PO Box 4382, 

Homebush South, New South Wales, 2140  

(Phone: (03) 5629 5833,  

Email: [email protected]; or

 

(b)   in the case of an Aqua-Gen 3/+ Series, AquaGen 

5 Series or SSV Series of Automatic Controllers, 

a three (3) year limited warranty from Dontek 

Electronics Pty Ltd, 19 Melrich Road, Bayswater, 

Victoria, 3153 (Phone: (03) 9762 8800,  

Email: [email protected]); or

 

(c)   in the case of an Aqua-Gen 2 Automatic Controller, 

a two (2) year limited warranty (temperature 

sensors not covered) from Dontek Electronics 

Pty Ltd, 19 Melrich Road, Bayswater, Victoria, 

3153 (Phone: (03) 9762 8800, Email: service@

dontekelectronics.com.au);

and is the only warranty given in respect of that part of the 

Product.

 The Solar Pump included in the Product carries:

(a)   in the case of an SSGL Series Solar Pump, a two (2) 

year limited warranty (six (6) months for commercial 

installations) from Supreme Solar Pty Ltd, 2/19 

Enterprise Drive, Bundoora, Victoria, 3083 (Phone: (03) 

9460 4200, Email: [email protected]);  or

(b)   in the case of an SunSol SS Series or Booster AB Series 

Solar Pump, a two (2) year limited warranty. Two (2) 

year warranty on the motor, pump body and seal plate, 

and a one (1) year warranty on the mechanical seal 

from Reltech Australia Pty Ltd, 43-45 Kylta Road, West 

Heidelberg, Victoria, 3081 (Phone: (03) 9459 3838,  

Email: [email protected]); 

A twelve (12) month in field labour warranty is applicable 

in Capital City Metropolitan areas or within a 20km radius 

of an Authorised Supreme Solar P/L or Reltech Australia P/L 

Service Agent.  
and is the only warranty given in respect of that part of the 

Product.

 All other components supplied by Supreme Solar Pty 

Ltd carry a twelve (12) month limited warranty and is 

the only warranty given in respect of these components 

of the Product.

Exclusions

 Supreme Solar Pty Ltd will not be liable under this 

warranty where Supreme Solar Pty Ltd’s reasonable 

opinion a defect is caused by:

 

(a)  fair wear and tear;

 

(b)  negligent, careless or improper use or handling;

 

(c)   non-adherence to operating, cleaning or 

maintenance instructions;

 

(d)   harsh or adverse Pool/Spa water conditions;

 

(e)   repair to or alteration of any parts of the system 

by any person who has not been authorised by 

Supreme Solar Pty Ltd to perform such a repair or 

alteration;

 

(f)   act of God, riot, fire or other occurrence outside 

normal working conditions; or

 

(g)   by other abuse or misuse caused by the Purchaser 

or a third party.

Summary of Contents for Heatseeker UniPanel

Page 1: ...User Manual SAAWARDSOF EXCELLENCE 2017GOLD QLD AWARDS OF EXCELLENCE 2017 GOLD AWARDS OF EXCELLENCE 2017 GOLD SAAWARDSOF EXCELLENCE 2017GOLD SA AWARDS OF EXCELLENCE 2017 GOLD SAAWARDSOF EXCELLENCE 201...

Page 2: ...ton Grange NSW 2567 P 02 4648 4766 solar nsw supremeheating com au salesnsw supremeheating com au QLD Office Brisbane QLD 4001 M 0455 064 765 solarqld supremeheating com au SA Office Wingfield SA 5013...

Page 3: ...mperature Setting Up and Down Buttons 09 Enter Button 10 ControllerTroubleshooting 11 No PowerToThe Display 11 Pipe Roof Sensor Faults 11 Pump Faults 12 Installer Setup 13 Additional Information 13 So...

Page 4: ...equipment Installation and service must be performed by a qualified installer The manufacturer will not be responsible for any damage to the system caused by improper installation operation or mainten...

Page 5: ...anel Solar Pool Heating 03 Specifications 48 3 MANIFOLD 43 PORT DETAIL 880 20 SLOT PORT DETAIL 1095 PORT TO PORT WIDTH 1136 PORT TO PORT WIDTH 1114 PANEL WIDTH ACROSS EDGES 1030 PANEL WIDTH ACROSS EDG...

Page 6: ...r flat roof is acceptable 2 Shade Try to avoid positioning the solar collectors on a roof that is going to be shaded heavily throughout the day The best solar gains are made three hours either side of...

Page 7: ...Heatseeker UniPanel Solar Pool Heating 05 Typical Arrangement...

Page 8: ...Heating 06 System Assembly Panel PVC Adaptor Port Insert Manifold Coupling Aluminium Rail Coupling Cover Manifold Fixing Clip Lock Nut Rail End Cap Rail Channel Slider Rail Joining Strip BOTTOM MANIFO...

Page 9: ...Heating 07 Accessories Rail Mounting System Accessories List Manifold Coupling Coupling Cover Manifold Port Insert Panel PVC Adaptor Manifold Fixing Clip Rail End Cap Rail Channel Slider Lock Nut Alu...

Page 10: ...nt heating manual and standby mode features Aqua Gen 5 Aqua Gen 5BR Aqua Gen 5PV To determine what model controller you have please refer to your quotation invoice or the model number can be found nea...

Page 11: ...required This is a better option than turning off the controller as it will flush treated pool water through the solar system as well as prolong pump bearing and mechanical seal life The pump will run...

Page 12: ...clock you will have to set the time of day Set hours then minutes 3 SYSTEM System sub menu EXIT COOLING LCDTIME HOURS SYSTEM SUB MENU EXIT Press on this menu to return to automatic operation COOLING...

Page 13: ...FAULTS Swap the sensor locations simply put the pipe sensor in the roof socket and the roof sensor in the pipe socket If the fault moves from pipe to roof or vice versa then you can be certain that t...

Page 14: ...operate then unplug it from the power point and connect it to the 240V socket marked PUMP at the bottom of the controller Apply power to the controller and if the pump starts instantaneously before t...

Page 15: ...anels cannot drain down and will require a wetted roof sensor for this mode CAL Calibrate the pool sensor Additional Information 1 If any of the menu items are left unattended for 3 minutes the menu w...

Page 16: ...ot use or operate swimming pools spas or spa baths if a suction cover is broken missing or loose Small children using the pool or spa must always have close adult supervision SS Series Solar Pump Oper...

Page 17: ...ed in the pipe work and pump may be expelled STEP 4 If prime is not established within approximately 2 minutes as evidenced by a strong flow of water from the outlet switch off the pump and repeat the...

Page 18: ...OT START Solar controller is not triggering pump to turn on Refer to controller instruction manual Pump is not plugged into power Blockage is preventing rotation Electrical failure Automatic overload...

Page 19: ...set to Pipe Protection Refer to controller operation instructions on page 08 Failure to observe this instruction may cause damage and void all warranties related to panels pipe work and fittings The s...

Page 20: ...ending on the size of the system and during this period the resulting turbulence created will cause some associated noise Vacuum relief valves should be inspected regularly 2 4 months during the month...

Page 21: ...O ring to ensure positive seal 3 Ensure electrical passage for cooling airflow to prevent fusing or shock hazards 4 Maintain a clear passage for cooling airflow to prevent overheating of motor 5 Main...

Page 22: ...es or SSV Series of Automatic Controllers a three 3 year limited warranty from Dontek Electronics Pty Ltd 19 Melrich Road Bayswater Victoria 3153 Phone 03 9762 8800 Email service dontekelectronics com...

Page 23: ...for any other loss or damage including consequential or indirect damages 11 Supreme Solar Pty Ltd reserves the right to charge the Purchaser at Supreme Solar Pty Ltd s current hourly rate for the cos...

Page 24: ...supremeheating com au 1300 787 978...

Reviews: