background image

4

Safety Precautions

 Caution

Use

Do not drop the product or subject it to impact or shock.

• 

This may cause malfunction.

Be careful not to interrupt power supply while firmware upgrade is in progress.

• 

This may cause malfunction.

Keep your password safe and change it periodically.

• 

Otherwise this could allow unauthorized access.

Do not press the buttons (touchpad) on the product with excessive force or with a sharp tool.

• 

This may cause malfunction.

Use the product at a temperature between -20°C and 50°C, and do not store it at temperatures that are too low 

or high.

• 

This may cause malfunction.

Clean the product with care.

• 

Gently wipe the surface of the product with a clean, dry cloth.

• 

If the product needs to be disinfected, apply an appropriate amount of rubbing alcohol to a dry cloth and then gently 
wipe the surface. Use rubbing alcohol that contains 70–75% isopropyl alcohol as well as a soft, clean, and lint-free cloth.

• 

Do not spray disinfectant directly on the product.

Do not use the product for purposes other than those it is intended for.

• 

This may cause malfunction.

RTC Battery

Use of an unapproved or incorrect type of battery may result in a risk of explosion. Dispose of batteries in compliance with 
local or international waste disposal regulations.

Summary of Contents for BioStation 3

Page 1: ...BioStation 3 INSTALLATION GUIDE English EN 101 00 BS3 00 ...

Page 2: ...a Relay 16 Fail Safe Lock 16 Fail Secure Lock 17 Connecting to an Automatic Door 18 Stand Alone Connection 19 Connecting to Secure I O 2 21 Wiegand Connection 22 Product Specifications 23 Dimensions 25 Regulatory Information 26 Regulatory Licenses 26 FCC Compliance Information 26 EU Declaration of Conformity CE 27 Appendix 28 Disclaimers 28 Copyright Notice 28 Open Source License 28 GNU General Pu...

Page 3: ...out an unauthorized installation or repair yourself Do not install the product in a place where it will be exposed to direct sunlight moisture dust or soot or in a place where there is a possibility of a gas leak This may cause a fire or electric shock If installing the product outdoors install it in a shaded and well ventilated place If installing the product outdoors do not use a fully closed of...

Page 4: ...s such as magnets TVs CRT monitors speakers etc This may cause malfunction When installing multiple devices ensure they are at the minimum distance required between the devices This may affect the RF and BLE performance of other devices and may cause malfunction Use an IEC EN 62368 1 compliant power adapter suited to the device s power consumption It is recommended to use a power adapter sold by S...

Page 5: ...peratures that are too low or high This may cause malfunction Clean the product with care Gently wipe the surface of the product with a clean dry cloth If the product needs to be disinfected apply an appropriate amount of rubbing alcohol to a dry cloth and then gently wipe the surface Use rubbing alcohol that contains 70 75 isopropyl alcohol as well as a soft clean and lint free cloth Do not spray...

Page 6: ...ce Software Linux Kernel GPL glibc LGPL OpenSSL Original SSLeay 306 00 V H Quick Guide Open Source Software Guide The components may vary depending on the installation environment When assembling the product with the bracket you can use the Bracket Fixing Screw Star Shaped instead of the Fixing Screws for a more secure installation To learn more about using this product please visit the Suprema we...

Page 7: ...es Visual Camera Captures actual images LCD Screen Provides the UI for actions RF Card and Mobile Access Card Reader Reads an RF card or mobile access card for access control LED Status Indicator Shows the operating status of the system Green Authentication successful Red Authentication failed Blue light blue flashing Normal operation Blue green flashing No IP address received while DHCP is enable...

Page 8: ...iegand output cable Wiegand Input 4 pin Connects the Wiegand input cable RS 485 4 pin Connects the RS 485 cable Relay 3 pin Connects the relay cable Power 2 pin Connects the power cable USB Type C Cable Slot Connects the USB cable Cables and Connectors Power Pin Name Color 1 PWR VDC Red white stripe 2 PWR GND Black white stripe Relay Pin Name Color 1 RLY NO White 2 RLY COM Blue 3 RLY NC Orange RS ...

Page 9: ... IN0 Red 2 TTL IN1 Yellow 3 TTL IN2 Orange 4 TTL GND Black 5 SH GND Grey Wiegand Input Pin Name Color 1 WG D0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Grey Wiegand Output Pin Name Color 1 WG D0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Grey ...

Page 10: ...t only one face appears on the screen Register one person at a time If you do not follow the instructions on the screen facial registration may take a long time or may fail Cautions regarding facial authentication Make sure your face appears in the center of the screen When the position guide is shown follow the on screen instructions for facial authentication If part of your face is covered by a ...

Page 11: ...stem be installed at a height of 136 cm Do not install the system in a location where it will be exposed to direct sunlight or ultraviolet rays Adjust the position of the system so that your face is not exposed to direct sunlight during facial authentication 2 Mount the bracket securely using the Bracket Fixing Screw at the position where the BioStation 3 is to be installed ...

Page 12: ...ll thickness Distance Wall Wall thickness Distance 100 mm 200 mm 120 mm 180 mm 150 mm 150 mm Wall 300 mm When using a mobile access card ensure there is a distance of at least 1 meter between the devices to avoid BLE interference 3 After applying the cable cover fix it securely by turning the six screws on the cover For IP65 compliance ensure you use a cable cover after connecting the product with...

Page 13: ...12 Installation 4 Mount the BioStation 3 on the fixed bracket Wall 5 Secure the BioStation 3 to the bracket with the BioStation 3 Fixing Screw Wall ...

Page 14: ...on to the distance between BioStation 3 and the power supply The system and the power supply should be as close as possible The system may malfunction if not properly connected If the system and power supply are far apart it is recommended to use 16 AWG or 18 AWG cable The connection distance available may vary depending on the size of the cable and the installation environment BioStation 3 suppor...

Page 15: ... BioStation 3 supports automatic MDI MDIX so it can be directly connected to a PC with a crossover cable or a normal straight type CAT 5 cable BioStation 3 PC See the information below when using a Gigabit Ethernet switch Use CAT 5e unshielded twisted pair UTP cable Use all 4 pairs 8 wires for network connection Do not use some of the pairs or wires for other purposes ...

Page 16: ...15 Installation Connecting to a TTL Input Cable shielding optional Sensor BioStation 3 Door sensor Exit button 1 TTL IN0 Red 2 TTL IN1 Yellow 3 TTL IN2 Orange 4 TTL GND Black 5 SH GND Grey ...

Page 17: ...ides of the lock wiring as shown in the illustration Use separate power sources for BioStation 3 and the lock For user convenience Suprema s intelligent device has an independent built in relay that can directly open or lock the door without a controller However for access control applications requiring enhanced security it is recommended not to use the built in relay in order to prevent tampering...

Page 18: ... lock wiring as shown in the illustration Use separate power sources for BioStation 3 and the lock For user convenience Suprema s intelligent device has an independent built in relay that can directly open or lock the door without a controller However for access control applications requiring enhanced security it is recommended not to use the built in relay in order to prevent tampering that could...

Page 19: ...18 Installation Connecting to an Automatic Door 1 3 BioStation 3 Exit button Door lock Automatic door controller Sensor 1 RLY NO White 2 RLY COM Blue ...

Page 20: ...TTL IN0 Red 2 TTL IN1 Yellow 3 TTL IN2 Orange 4 TTL GND Black 5 SH GND Grey Cable shielding optional TTL Power Relay Sensor For user convenience Suprema s intelligent device has an independent built in relay that can directly open or lock the door without a controller However for access control applications requiring enhanced security it is recommended not to use the built in relay in order to pre...

Page 21: ...ly one BioStation 3 can be added as a slave device If BioStation 3 is the master device and BioStation 3 is connected as a slave device Secure I O 2 and DM 20 one of each can be connected additionally If BioStation 3 is the master device and BioStation 3 is connected as a slave device OM 120 cannot be connected additionally The maximum number of slave devices that can be connected depends on the a...

Page 22: ...Station 3 as a control system for multiple doors The slave device is used as a dummy reader and authentication is performed by the master device If a fingerprint scanner is configured as a slave device for BioStation 3 another BioStation 3 cannot be added as a slave device If the fingerprint scanner is the master device BioStation 3 cannot be added as a slave device If BioStation 3 is the master d...

Page 23: ...ction Used as a Wiegand input device BioStation 3 RFID reader 1 WG D0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Grey Used as a Wiegand output device BioStation 3 Controller 1 WG D0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Grey ...

Page 24: ... LCD LCD resolution 720 x 1280 pixels Sound 16bit Operating temperature 20 C to 50 C Storage temperature 40 C to 70 C Operating humidity 0 to 80 non condensing Storage humidity 0 to 90 non condensing Camera 2 MP 2EA Dimensions W x H x D 82 5 x 171 x 23 4 mm Weight Device BS3 DB 370 g BS3 APWB 380 g Bracket 90 g Including washers and bolts IP rating IP65 IK rating IK06 Certifications CE FCC KC RoHS...

Page 25: ...2 V current 2 5 A or DC 24 V current 1 2 A Switch input VIH Min 3 V Max 5 V Switch input VIL Max 1 V Switch pull up resistor 4 7 kΩ The input ports are pulled up with 4 7 kΩ Wiegand output VOH 4 8 V or higher Wiegand output VOL 0 2 V or lower Wiegnad output pull up resistor Internal pull up to 1 kΩ Relay 2 A 30 VDC Resistive load 1 A 30 VDC Inductive load The DESFire EV2 card is backward compatibl...

Page 26: ...25 Product Specifications Dimensions Unit mm 171 82 5 23 4 164 72 9 ...

Page 27: ...its are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cau...

Page 28: ...ts and other relevant provisions of Radio Equipment Directive RED 2014 53 EU Bluetooth transmit power 0 1 dBm Bluetooth frequency 2402 2480 MHz NFC frequency 13 56 MHz RFID frequency 13 56 MHz 125 kHz For more information please contact us via the contact details below Suprema Inc Website https www supremainc com Address 17F 5 Parkview Office Tower 248 Jeongjail ro Seongnam si Gyeonggi do 13554 Re...

Page 29: ...rm of authentication messages and other relevant information during use of the products Suprema is not responsible for any information stored in Suprema products including personal information which is not directly under Suprema s control or specified in any relevant agreement When using information stored in products including personal information users of the products are responsible for complyi...

Page 30: ...the recipients the same freedoms that you received You must make sure that they too receive or can get the source code And you must show them these terms so they know their rights Developers that use the GNU GPL protect your rights with two steps 1 assert copyright on the software and 2 offer you this License giving you legal permission to copy distribute and or modify it For the developers and au...

Page 31: ...The source code for a work means the preferred form of the work for making modifications to it Object code means any non source form of a work A Standard Interface means an interface that either is an official standard defined by a recognized standards body or in the case of interfaces specified for a particular programming language one that is widely used among developers working in that language...

Page 32: ...u may convey verbatim copies of the Program s source code as you receive it in any medium provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice keep intact all notices stating that this License and any non permissive terms added in accord with section 7 apply to the code keep intact all notices of the absence of any warranty and give all recipients ...

Page 33: ...rary need not be included in conveying the object code work A User Product is either 1 a consumer product which means any tangible personal property which is normally used for personal family or household purposes or 2 anything designed or sold for incorporation into a dwelling In determining whether a product is a consumer product doubtful cases shall be resolved in favor of coverage For a partic...

Page 34: ... and authors All other non permissive additional terms are considered further restrictions within the meaning of section 10 If the Program as you received it or any part of it contains a notice stating that it is governed by this License along with a term that is a further restriction you may remove that term If a license document contains a further restriction but permits relicensing or conveying...

Page 35: ...ms are all patent claims owned or controlled by the contributor whether already acquired or hereafter acquired that would be infringed by some manner permitted by this License of making using or selling its contributor version but do not include claims that would be infringed only as a consequence of further modification of the contributor version For purposes of this definition control includes t...

Page 36: ...raction through a network will apply to the combination as such 14 Revised Versions of this License The Free Software Foundation may publish revised and or new versions of the GNU General Public License from time to time Such new versions will be similar in spirit to the present version but may differ in detail to address new problems or concerns Each version is given a distinguishing version numb...

Page 37: ...ed Work means the Corresponding Source for the Combined Work excluding any source code for portions of the Combined Work that considered in isolation are based on the Application and not on the Linked Version The Corresponding Application Code for a Combined Work means the object code and or source code for the Application including any data and utility programs needed for reproducing the Combined...

Page 38: ...f you use option 4d0 the Installation Information must accompany the Minimal Corresponding Source and Corresponding Application Code If you use option 4d1 you must provide the Installation Information in the manner specified by section 6 of the GNU GPL for conveying Corresponding Source 5 Combined Libraries You may place library facilities that are a work based on the Library side by side in a sin...

Page 39: ...s derived from this software may not be called OpenSSL nor may OpenSSL appear in their names without prior written permission of the OpenSSL Project 6 Redistributions of any form whatsoever must retain the following acknowledgment This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org THIS SOFTWARE IS PROVIDED BY THE OpenSSL PROJECT AS I...

Page 40: ... the following disclaimer in the documentation and or other materials provided with the distribution 3 All advertising materials mentioning features or use of this software must display the following acknowledgement This product includes cryptographic software written by Eric Young eay cryptsoft com The word cryptographic can be left out if the routines from the library being used are not cryptogr...

Page 41: ...names and numbers herein are registered trade marks of Suprema Inc All non Suprema brands and product names are trademarks or registered trademarks of their respective companies Product appearance build status and or specifications are subject to change without notice For more information about Suprema s global branch offices visit the webpage below by scanning the QR code https supremainc com en ...

Reviews: