background image

von-Drais-Straße 7 • D-55469 Simmern / Hunsrück • Tel: +49 6761 96509-00 • Fax: -01 • www.oxyflex.de • [email protected] (Status Dec. 2018)

Levelling
The OXYFLEX

®

- MF1100 membrane plate diffuser is mounted onto distribution pipes (round or square pipe

depending on version). The distribution pipes must be levelled to a maximum of ± 10 mm.

For installation on round pipes with Supratec supporters,
the pipe clamps must be tightened with torque of 10 Nm
(M10); 20 Nm (M12). The surface pressure that this
produces ensures that installation is distortion-free.
Threads have to be lubricated before screwing the nuts to
avoid seizing.

Type 'B': Installation on square pipe
The OXYFLEX

®

- MF1100 type 'B' membrane plate diffuser is mounted on a square pipe (width at least 60 mm)

with 4 threaded bolts M6 x 35 mm.
An EPDM gasket is inserted between the diffuser and the distribution pipe. The surfaces must be clean and
straight. Gasket must sit clean and undamaged between the diffuser and the pipe.
The distance between the bolts is 227 x 30 mm (see sketch). We would be pleased to provide you with an
appropriate welding template. The air-socket Ø = 29 mm is inserted from above into the bore hole Ø = 30 mm of
the square pipe and bolted in place using the threaded bolt that is now protruding from the side fastening lug of the
diffuser frame with washers and self-locking nuts M6 (4 Nm). The threaded bolts must be lubricated beforehand to
avoid seizing.
Always make sure that the diffuser is firmly and horizontally seated.

Washer 6,4 DIN 9021

Self-locking nut M6 DIN 985

Gasket Ø 38/30 x 10 (EPDM)

threaded bolt M6 x 35

30 mm

Summary of Contents for OXYFLEX MF1100

Page 1: ...d coarse bubble diffusion of liquids INSTALLATION OPERATING and MAINTENANCE INSTRUCTIONS The OXYFLEX MF1100 membrane plate diffuser consists of a flat heavily ribbed base plate with air sockets A two...

Page 2: ...000 mm differences possible on request In the vicinity of the mixer optional side brackets provide additional stability and make area wide coverage possible in this case as well independently of the t...

Page 3: ...is mounted on a square pipe width at least 60 mm with 4 threaded bolts M6 x 35 mm An EPDM gasket is inserted between the diffuser and the distribution pipe The surfaces must be clean and straight Gas...

Page 4: ...is inserted into the hole of the round pipe from above An O ring made from EPDM is inserted between the upper part of the clamp saddle and the distribution pipe The gasket between the diffuser and the...

Page 5: ...screwed in place with the counter piece at the opposite side using an M10 hexagonal through screw 16 Nm The thread of the hexagon screws have to be lubricated beforehand to avoid seizing An O ring mad...

Page 6: ...see run in of diffusers in table 1 on page 8 TPU membranes OXYFLEX MF1100 membrane plate diffusers with TPU membranes do not have to be run in for normal operation However a bubble pattern test or an...

Page 7: ...ble pattern and the pressure loss should be checked and documented at regular intervals under similar operating conditions such as water level and air quantity The pressure loss development in the loa...

Page 8: ...rably from older membranes with regard to pressure loss We would be pleased to provide advice if necessary Table 1 Specific loads h m3 N per diffuser for the OXYFLEX MF1100 membrane plate diffuser wit...

Reviews: