background image

40730-06-16

GB 5/8

PERSEE

W

W

ARNING

ARNING

- This wood stove is designed to operate with the door closed. The

door must remain closed at all times except when loading.

- Leave a space of at least 5 cm between the bottom of the stovebox

and the top of the logs.

- To avoid any risk of burns, do not touch the appliance and use the

glove to operate the different controls.

- The heat radiation through the glass requires that any material that

may be damaged or affected by the heat should be removed (furniture,

wallpaper, woodwork, etc.). A distance of 2 m is sufficient to avoid

any risk.

3.1. FUEL

3.1.1. Wood

Burn only firewood, in log form, air-dried (2 to 3 years storage in a well venti-
lated, sheltered place) with 15 to 20 % humidity maximum.
- Choose hard deciduous woods if possible (birch, hornbeam, beech...),
- Avoid soft woods (lime, chestnut, willow, poplar)
- Never use coniferous woods (pine, fir...) for permanent use, or treated

used woods  (railway sleepers, joiners' cut-offs...) and domestic waste
(vegetable materials or plastics).

- Never  make a blaze with armfuls of kindling, crates, small logs or vine

shoots which can cause sudden overheating.

3.1.2. Lignite

Used in normal operation (daytime) or for slow burning (night use), alone
or with wood, the lignite briquette is an economical fuel.
Place the briquettes in a layer over a bed of embers, covering only the
surface of the grate.

3.2. DRAUGHT

The draught in the smoke flue when hot must never exceed 20 Pa. If the
draught is greater, install a draught adapter. Consult your dealer in order to
have the draught measured when the stove is installed. The presence of a
controlled mechanical ventilation system may have an effect on the draught
value and even reverse it. For this reason, the extractor must be in operation
when the draught is measured.

3.3. FIRST LIGHTING

Remove the sticky labels (except signage), any packaging cardboard and
ensure that there is nothing in the ashbox.
Start with a small fire then, in stages, increase the load. This progressive
rise in the temperature allows the materials to dilate slowly and stabilise.

Smoke and a smell will be given off at first (due to the presentation paint)
but this will fade in time. Proceed in this way for several days before beginning
normal use. Open the windows during the first few times.
During the first heating, check the draught against the table of technical
characteristics, and adjust the draft regulator if necessary.
.

3.4. OPERATION

3.4.1. Lighting

Spread some crumpled paper on the bottom of the stove, place some kindling
on top and some small spit logs. Position the controls as shown in Table

W

W

ARNING!

ARNING! The use, even occasionally, of coal or any coal

derivative is strictly prohibited. This appliance must not be used

to burn domestic waste!

3. USE

Tab. 3.1

PERSEE

lighting

nominal

mini

Grid air 

Glass air

open

open

open

open

closed

1/2 closed

-

+

Commande 

Air de vitre

3.1 COMMANDES

(SCHÉMA INDICATIF)

-

+

Commande 

Air de combustion

PERSEE

Summary of Contents for PACCO HAUT

Page 1: ...s non contractual connecting pipe not supplied Page 1 TECHNICAL CHARACTERISTICS 3 2 INSTALLATION 4 3 USE 5 4 MAINTENANCE 6 5 AFTER SALES SERVICE 6 PERSEE SUR B CHER PERSEE PERSEE SUR PIED PACCO HAUT S...

Page 2: ...tion Before using your stove for the first time read carefully the brochure Recommendations for the installation of wood burning heating apparatus as well as these instructions for installation and us...

Page 3: ...appliance must be installed in accordance with the specifications of the standards 1 in force Installation by a qualified professional is recom mended The instructions in this booklet must be followe...

Page 4: ...stove in its final position and adjust the level For the floor of the loading area in front of the stove we recommend ceramic tiles for example to facilitate maintenance 2 4 SMOKE BAFFLE FIG 2 2 The...

Page 5: ...T The draught in the smoke flue when hot must never exceed 20 Pa If the draught is greater install a draught adapter Consult your dealer in order to have the draught measured when the stove is install...

Page 6: ...n a sufficient supply of fresh air To reduce maintenance use the stove at nominal speed whenever possible 3 6 LOADING THE STOVE Load in several goes rather than too much one at once Place the wood tow...

Page 7: ...e window during normal operation When operating at reduced speed the clean glass system does not work 4 4 OBLIGATORY CHIMNEY SWEEPING The law requires that the chimney be swept twice a year including...

Page 8: ...40730 06 16 PERSEE SUPRA FRANCE RCS Saverne 441 048 576 SIRET 441 048 576 00074 BP 22 67216 OBERNAI Cedex FRANCE www supra fr...

Reviews: