40730-06-16
GB 3/8
PERSEE
- IMPORTANT ASSEMBLY INFORMATION -
Your chimney "draws well", but you probably do not know the degree of negative pressure. The negative pressure or draught in a chimney
is measured in Pascals (Pa). All inserts, closed fires and fires are designed, optimised and built according to French standards NF 13229
(or NF 13240) to operate connected to a chimney duct whose nominal draught is 12 Pa. Very often (more than one chimney in two), the
draught is too strong (over 20 Pa). This can be due to the chimney being too high or an installation with tubing. The fires then operate in
abnormal conditions, leading to:
- Excessive wood consumption: this may be three times more than for a fire operating with a draught of 12 Pa.
- A fire that does not last, burning much too fast and giving off very little heat.
- The rapid and irreparable deterioration of the fire (cracks in the cast iron hearth plate or firebricks).
- The invalidation of the guarantee.
To avoid all these problems, there is only one solution.
Have your chimney’s draught checked (with the fire in operation) by a professional and if it is over 20 Pa, install a draught regulator on the
fire’s connection pipe.
- WARNING -
- This appliance is intended to burn wood, on no account may it be used as an incinerator or to burn liquid fuels, coal or derivatives.
- All local or national regulations, as well as the European standards
(1)
must be respected as well as the European standards(1) when installing and
using the appliance.
- The heating appliance is hot when in use, particularly the glazed front. It remains hot for a long time, even if the flames are no longer visible. Take
precautions to avoid all contact with the appliance (young children in particular).
- Before accessing the electrical connection parts, all the power circuits must be switched off.
- This appliance must be installed in accordance with the specifications of the standards
(1)
in force. Installation by a qualified professional is recom-
mended.
- The instructions in this booklet must be followed scrupulously. Keep these instructions in a safe place.
- The manufacturer's liability is limited to the supply of the appliance. It may not be held liable in the event of any failure to respect these instructions.
- The following are especially prohibited:
- The installation of materials that may be affected or damaged by the heat (furniture, wallpaper, woodwork) too close to the fire.
- The installation of any heat regenerator other than those recommended by the manufacturer.
- The use of any fuel other than natural wood and lignite.
- Any modification to the appliance or the installation not provided for by the manufacturer, which would release it from its liability and cancel the warranty.
Use exclusively spare parts recommended by the manufacturer.
- Any failure to comply with these indications is entirely the responsibility of the person who carries out the work and assembles the fire.
1.
1.
TECHNICAL
TECHNICAL
CHARACTERISTICS
CHARACTERISTICS
STOVE
PERSEE
Category of stove
Continuous
Rated heating output
(1)
8 kW
Operation with door closed only
Type of connection
horizontal
Average temperature of smoke with door closed
307 °C
Efficiency
75,7 %
CO rate (13% O2)
0,25 %
Fuels
firewood
Log size
33 cm max
Nominal/max. hourly load
1,5 kg
Reloading intervalt
1 h
Alternative fuel
lignite
Prohibited fuels
all others, including coal and derivatives
Mass flow of smoke
4,9 g/s
Nominal diameter of smoke outlet
120/125 mm
Characteristics of smoke flue
Minimum dimensions of chimney block
20 x 20 cm
Min.Ø of tubing or insulated metal flue
125 mm
Min. height of flue above fire
4 m
Ventilation of room
1 dm²
Draught ( (10 Pa = 1 mm CE)
Nominal speed
12 Pa ± 2 Pa
Reduced speed (min. admissible)
6 Pa ± 1 Pa
Max. admissible
20 Pa
Net / gross weight
95/105 kg
Manufacturer's plate
behind the ashbox
Accessories supplied
Insulated glove