background image

You should have: 

•  1 Radiator
•  4 Bracket Closing Caps
•  4 Bracket Hooks
•  4 Bracket Back Plates
•  4 Bracket Screws

You will need: 

•  Tape measure
•  Electric drill and bits
•  Spirit level 
•  Airvent key
•  Appropriate wall fixings
•  Spanner for valves and  
     vents

2. Contents

Technical Specifications

Materials

 

  

Aluminium

Connections

     

   

½" flow and return.

Test pressure

 

                       9 Bar

Testing authority

 

  

EN442

Maximum operating pressure

 

6 Bar

Maximum working temperature 

90 ºC 

Packaging

 

   

Polystyrene protection in cardboard box

All products must be inspected once removed 
from the packaging and your point of purchase 
notified within 28 days of delivery of any 
scratches, blemishes or other damage. Your 
point of purchase will then agree appropriate 
action.
Imperfect radiators should therefore not be 
fitted and we will not accept responsibility for 
replacement of scratched or damaged radiators 
once they have been fitted. This includes any 
consequential loss or cost of fitting. 
If we are not notified within 28 days of the 
date on the signed delivery note then it will be 
deemed that we have fully complied with our 
obligations and claims will not be considered. 
Failure to comply with any of the above may 
invalidate any claims. We recommend that 
after you check the product on delivery that it is 
stored in its packaging to prevent damage prior 
to installation, we cannot accept responsibility 
for items damaged after delivery.
For full details of our Terms and Conditions 
please visit www.supplies4heat.co.uk or call us 
on 01342 306880.

Terms & Conditions

This product is guaranteed for 10 years. As we are not the manufacturers of this product 
we will take all reasonable endeavours to make over to you the benefit of any warranty 
or guarantee given by the manufacturer.
The guarantees in all cases are subject to the products being installed in accordance with 
British and or European standards as well as these fitting instructions. The guarantees in 
all cases are restricted to the free of charge replacement or repair of the failed product 
only. Our liability will under no circumstances extend beyond the repair or replacement 
of the product supplied by us. Claims for either labour in replacement or damage to 
property are not admissible. Any goods that are returned, in the event of a problem, 
will belong to us.

Guarantees & Liabilities

www.supplies4heat.co.uk    01342 306880

Refer to diagrams overleaf when installing

 

 
1. Accurately mark bracket holes on the wall using a tape measure 
and spirit level. The bracket centres are positioned 153mm down 
from the top collector, and 103mm from either side. 
(Height of the radiator from floor : minimum 100mm)  
 
2. Using suitable drill bits and plugs, insert suitable wall plugs. To 
hang the top two brackets, secure the backplate ‘A’ with screws ‘B’ 
(or other suitable screws) going through into the wall plugs. 
 
3. Insert the bracktets ‘C’ down into the back plate ‘A’ and secure 
with the provided screw ‘D’. Then fit the closing cap ‘E’ on top. 

3. Installing radiator

Please Note: In accordance with Part L1 2006 of 

the Building Regulations and BS7593:1992 code of 

practice for the treatment of hot water and central 

heating systems, we strongly recommend flushing 

the heating system post installation of new radiators 

and then adding the correct quantity and type of 

inhibitor for use with your radiator and system to 

prevent corrosion. Damage caused to systems not 

protected by a suitable inhibitor will not be covered 

by manufacturer’s guarantee.

5. Commission Radiator

Please Note: 

the diverter is marked with a yellow 

cap and is fitted on the radiator. The diverter can 
be removed and swapped to the other side if 
required. However, we will not be liable for any 
damages to the radiator or paint finish as a result 
of moving the diverter. 

4. Hang the radiator on the 

second space

 

5. With the brackets in the correct position, 
take down the radiator and fit the bottom 
two brackets by repeating steps 1 to 4. 

E

D

C

A

PLEASE NOTE:

 To reduce the possibility of noise caused by rapid heating and cooling 

of aluminium radiators; adequate capacity for expansion must be provided within 
the overall heating system. Systems using micro bore pipework must have adequate 
pressure and flow rates for the number and style of radiators on the system.

Reviews: