You should have:

•  1 Radiator
•  4 Wall brackets (3 wall brac. for single 2 elements)
•  4 Wall Plugs (3 wall plugs for single 2 elements)
•  4 Screws (3 wall screws single 2 elements)
•  4 Wall sleeves (3 wall sleeves for single 2 elements)
•  1 Airvent
•  1 Blanking Plug

You will need:

•  Tape measure
•  Electric drill and bits
•  Spirit level

2. Contents

Beaufort Slim single radiators use clamp style brackets 
that can be positioned on the collector to suit the 
installation, although we recommend that they are fitted 
in the locations suggested in the technical drawings in 
section 

5. Fit Brackets & Hang.

 

The brackets on double radiators use welded lugs in fixed 
positions on the cross tubes.
Attach brackets and bracket sleeves to the radiator 
as shown in Diagrams 1 (single) and 2 (double), place 
radiator against the wall and mark bracket positions. 

Detach the bracket sleeve from the bracket and using a 
suitable drill bit and fixings secure in position, checking 
they are level and square.

PLEASE NOTE :
It is essential that all brackets are level to ensure a vertical 
alignment for connecting the pipework.

3. Mark Bracket Positions

All products must be inspected once removed from the 
packaging and your point of purchase notified within 28 days 
of delivery of any scratches, blemishes or other damage. Your 
point of purchase will then agree appropriate action.
Imperfect radiators should therefore not be fitted and we 
will not accept responsibility for replacement of scratched or 
damaged radiators once they have been fitted. This includes 
any consequential loss or cost of fitting. 
If we are not notified within 28 days of the date on the 
signed delivery note then it will be deemed that we have 
fully complied with our obligations and claims will not be 
considered. 
Failure to comply with any of the above may invalidate any 
claims. We recommend that after you check the product on 
delivery that it is stored in its packaging to prevent damage 
prior to installation, we cannot accept responsibility for items 
damaged after delivery.
For full details of our Terms and Conditions please visit 

supplies4heat.co.uk

 or call us on 

01342 306880.

Terms & Conditions

This product is guaranteed for 10 years.The guarantees in all cases are subject to the 
products being installed in accordance with British and or European standards as well 
as these fitting instructions. The guarantees in all cases are restricted to the free of 
charge replacement or repair of the failed product only. Our liability will under no 
circumstances extend beyond the repair or replacement of the product supplied by 
us. Claims for either labour in replacement or damage to property are not admissible. 
Any goods that are returned, in the event of a problem, will belong to us.

Guarantees & Liabilities

5. Fit Brackets & Hang

Technical Specifications

Materials

 

  

  Steel.

Connections

     

   

½” flow and return.

Test pressure

 

   

5.2 Bar

Maximum operating pressure

 

 

4 Bar

Maximum working temperature 

 

As to EN442 ∆t 50ºC 

Packaging

 

   

 

Wrapped in polythene & boxed

supplies4heat.co.uk    01342 306880

PLEASE NOTE: 

Systems using micro bore pipework must have adequate pressure 

and flow rates for the number and style of radiators on the system.

Unpack & Inspect

1

You should have:

•   1 Radiator
•  4 Wall brackets (3 wall brac. for single 2 elements)
•  4 Wall Plugs (3 wall plugs for single 2 elements)
•   4 Screws (3 wall screws single 2 elements)
•  4 Wall sleeves (3 wall sleeves for single 2 elements)
•  1 Airvent 
•  1 Blanking Plug

You will need:

•  Tape measure
•  Electric drill and bits
•  Spirit level

Contents

Mark  and Fix Brackets

3

Diagrams of Water Lily

The Radiator Company prides itself on selecting products from 
manufacturers who exercise tight quality control measures. We only 
select models with excellent standards of welding and brazing, as 
well as high quality finishes. All of our products are well packaged 
and should reach you in perfect condition. Just in case however, we 

offer a minimum 10 year no quibble guarantee 
for all radiators and towel rails.
Please carefully unpack and inspect this radiator 
and all fittings. The Radiator Company must be 
notified of any shortages or damage within 28 
days of delivery. For further information please 
see terms and conditions on back page.

Water Lily single radiators use clamp style brackets that can be 
positioned on the collector to suit the installation, although we 
recommend that they are fitted in the locations suggested in the 
technical drawings in section 5. The brackets on double radiators use 
welded lugs in fixed positions on the cross tubes.
Attach brackets and bracket sleeves to the radiator as shown in 
Diagrams 1 (single) and 2 (double), place radiator against the wall 
and mark bracket positions. 
Detach the bracket sleeve from the bracket and using a suitable drill 
bit and fixings secure in position, checking they are level and square.

Pipe Centres

Pipe centres left to right 

width - 84 mm

 
Pipe centres from wall 

Single;

  55 mm - 65 mm

 

 

   

Double;

  67 mm - 77 mm

Depth from wall  

Single;

  79 mm - 89 mm

 

 

   

Double;

  91mm - 101mm

Please note: underneath connections only

Commision

Please Note: In accordance with Part L1 2006 of the Building Regulations 
and BS7593:1992 code of practice for the treatment of hot water and central 
heating systems, we strongly recommend flushing the heating system post 
installation of new radiators and then adding the correct quantity and type 
of inhibitor for use with your radiator and system to prevent corrosion. 
Damage caused to systems not protected by a suitable inhibitor will not be 
covered by manufacturer’s guarantee. 

= typical bracket fixing positions for single range

5

Fix Brackets and Hang 

With the bracket sleeves firmly fixed and level, the radiator can 
be hung in position by inserting the brackets into the sleeves and 
securing with the grub screws provided.

Hang Radiator

4

PLEASE NOTE :

It is essential that all brackets are level to ensure a vertical alignment for 
connecting the pipework.

single range

double range

79÷89

55÷65

L’

L

H’

H

91÷101

67÷77

Model

Elem.

H

H’

H

H’

L

L’

mm

mm

mm

mm

mm

mm

Water Lily

Single 

& double

2

1820

1762

2020

1962

160

76

3

1820

1762

2020

1962

236

152

4

1820

1762

2020

1962

312

228

5

1820

1762

2020

1962

388

304

6

1820

1762

2020

1962

464

380

= bracket fixing positions for double range

2

Diagram 1 (single version)

Diagram 2 (double version)

Please Note: In accordance with Part L1 2006 of the Building Regulations 
and BS7593:1992 code of practice for the treatment of hot water and central 
heating systems, we strongly recommend flushing the heating system post 
installation of new radiators and then adding the correct quantity and type 
of inhibitor for use with your radiator and system to prevent corrosion. 
Damage caused to systems not protected by a suitable inhibitor will not be 
covered by manufacturer’s guarantee.

With the bracket sleeves firmly fixed and level, the radiator 
can be hung in position by inserting the brackets into the 
sleeves and securing with the grub screws provided.

4. Hang Radiator