2-20
X10DRH-C/CT/i/iT Motherboard User’s Manual
BIOS
LICENSE
MAC CODE
BAR CODE
X10DRH-C/i(T)
Rev. 1.00
1
2
Ground
19
20
NMI
X
X
FP PWRLED
3.3 V
HDD LED
UID Switch
NIC1 Link LED
NIC1 Activity LED
NIC2 Link LED
NIC2 Activity LED
UID LED
OH/Fan Fail/
PWR Fail LED)
Power Fail LED
3.3V
Reset Button
Power Button
Ground
Ground
1. UID Switch
2. Rear UID LED
3. Front UID LED (on pin 7 of JF1)
4. Front UID Switch (on pin 13 of JF1)
3
1
2
Unit Identifier Switches/UID LED
Indicators
A rear Unit Identifier (UID) switch and a
rear UID LED (LE1) are located next to the
VGA port on the motherboard. The front UID
switch and the UID LED are both located on
the front panel control (JF1), with the front
UID switch on pin 13 of JF1 and the front
LED on pin 7. When you press either the
front or rear UID switch, both front and rear
UID LEDs will be turned on. Press the UID
switch again to turn off the LED indicators.
The UID indicators provide easy identifica
-
tion of a system unit that may be in need
of service.
Note:
UID can also be triggered via
IPMI on the motherboard. For more
information on IPMI, please refer
to the IPMI user's guide posted on
our website @ http://www.super-
micro.com.
UID Switch
Pin# Definition
1
Ground
2
Ground
3
Button In
4
Ground
UID LED
Status
Color/State Status
Blue: On
Unit Identified
4
1