2-4
S
UPER
S
ERVER 7045W-NTR+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack
installation requires the use of the optional rackmount kit. If the system has already
been mounted into a rack or if you are using it as a tower, you can skip ahead to
Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. The following is a guideline for installing the server into
a rack with the rack rails provided in the rackmount kit. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit includes two rack rail assemblies. Each of these as-
semblies consist of three sections: an inner fi xed chassis rail that secures to the
chassis, an outer rack rail that secures directly to the rack itself and two rail brackets,
which also attack to the rack (see Figure 2-1.) The inner and outer rails must be
detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Depress the locking tab to pull the inner rail completely out. Do this for
both assemblies (one for each side).
Figure 2-1. Identifying the Sections of the Rack Rails
Inner rail
Outer rail
Rail brackets
Summary of Contents for SUPERSERVER 7045W-NTR+
Page 1: ... SUPERSERVER 7045W NTR SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 28: ...3 4 SUPERSERVER 7045W NTR User s Manual Notes ...
Page 58: ...5 26 SUPERSERVER 7045W NTR User s Manual Notes ...
Page 102: ...A 6 SUPERSERVER 7045W NTR User s Manual Notes ...
Page 108: ...B 6 SUPERSERVER 7045W NTR User s Manual Notes ...
Page 122: ...C 14 SUPERSERVER 7045W NTR User s Manual Notes ...
Page 146: ...E 4 SUPERSERVER 7045W NTR User s Manual Notes ...