Chapter 7: AMI BIOS
7-23
Legacy Console Redirection Settings
Legacy Console Redirection Port
Choose a COM port to display redirection of legacy OS and legacy OPROM
messages. The options are
COM1
or SOL/COM2.
Serial Port for Out-of-Band Management/Windows Emergency Management
Services (EMS)
EMS Console Redirection
Select Enabled to use a COM Port selected by the user for Console Redirection.
The options are Enabled and
Disabled
.
Console Redirection Settings (for EMS)
The submenu allows the user to configure Console Redirection settings to
support Out-of-Band Serial Port management. The settings specify how the host
computer will exchange data with the remote computer (used by the user). Both
computers should have the same or compatible settings.
Out-of-Band Management Port
The setting selects a serial port used by the Microsoft Windows Emergency
Management Services (EMS) to communicate with a remote server. The options
are
COM1 Console Redirection
and COM2/SOL Console Redirection.
Terminal Type
This setting allows the user to select the target terminal emulation type for
Console Redirection. Select VT100 to use the ASCII character set. Select
VT100+ to add color and function key support. Select ANSI to use the extended
ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode
characters into one or more bytes. The options are ANSI, VT100, VT100+, and
VT-UTF8
.
Bits Per Second
This item sets the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and
the client computer. A lower transmission speed may be required for long and
busy lines. The options are 9600, 19200, 57600, and
115200
(bits per second).
Flow Control
This item allows the user to set the flow control for Console Redirection to
prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending
Summary of Contents for SuperServer 6028U Series
Page 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 6028U Series...
Page 12: ...1 6 SUPERSERVER 6028U Series User s Manual Notes...
Page 44: ...4 20 SUPERSERVER 6028U Series User s Manual Notes...
Page 79: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 9 Expansion and Riser Cards Front View...
Page 83: ...Chapter 6 Advanced Chassis Setup 6 13 Figure 6 9 Removing Replacing the Power Supply...
Page 84: ...6 14 SUPERSERVER 6028U Series User s Manual Notes...
Page 118: ...A 2 SUPERSERVER 6028U Series User s Manual Notes...