Chapter 5: Advanced Motherboard Setup
5-11
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
defi nitions.
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
5
Vcc
6
Ground
Overheat/Fan Fail
Connect an LED to pins 7 and 8 of
JF1 to indicate fan fail and provide
advanced warning of chassis over-
heating. Refer to the table on the right
for pin defi nitions.
HDD LED Switch
The HDD LED and UID switch con-
nections are located on pins 13 and
14 of JF1. Attach a cable here to in-
dicate disk activity (for any hard drive
activities on the system, including
Serial ATA and IDE). See the table on
the right for pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc
8
Ground
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9
Vcc
10
Ground
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13
Vcc
14
HD Active
NIC2 (LAN2) LED
The LED connections for LAN2 are on
pins 9 and 10 of JF1. Attach an LED
cable to display network activity. See
the table on the right for pin defi ni-
tions. (LAN2 on 5015A-H only.)
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11
Vcc
12
Ground
NIC1 (LAN1) LED
The LED connections for LAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
defi nitions.
OH/Fan Fail Indicator
Status
State Defi nition
Off
Normal
On
Overheat
Flashing
Fan Fail
Summary of Contents for Supero SUPERSERVER 5015A-H
Page 1: ... SUPER USER S MANUAL Revision 1 0 SUPERSERVER 5015A L SUPERSERVER 5015A H ...
Page 5: ...v Preface Notes ...
Page 14: ...1 6 SUPERSERVER 5015A L 5015A H User s Manual Notes ...
Page 26: ...3 4 SUPERSERVER 5015A L 5015A H User s Manual Notes ...
Page 50: ...5 20 SUPERSERVER 5015A L 5015A H User s Manual Notes ...
Page 76: ...7 20 SUPERSERVER 5015A L 5015A H User s Manual Notes ...
Page 78: ...A 2 SUPERSERVER 5015A L 5015A H User s Manual Notes ...