Rebuilding Arrays
*Note 1:
Rebuilding applies to Fault Tolerant array (RAID 1) only.
If an array Build process (or initialization) is interrupted or critical with
one member missing, you must perform a Rebuild to get the array to
Optimal status. For a critical array Rebuild operation, the optimal drive is
the source drive.
*Note 2:
If no spare array exists and a hard disk drive fails, you need to
create a spare before you can rebuild an array.
To Rebuild an array:
1
From the Main Menu, select
Manage Arrays
(as shown in the screen
below). From the List of Arrays, select the array you want to Rebuild.
2
Press
Ctrl+R
to Rebuild.