SC811 Chassis Manual
4-8
4-7 Installing the Air Shroud
Air shrouds concentrate airflow to maximize fan efficiency. The SC811 chassis air
shroud does not require screws to set it up.
Installing the Air Shroud
1. Remove the mylar air shroud from the accessories box.
2. If necessary, bend the air shroud so the sides air at a ninety degree angle to
the top.
3.
Place air shroud in the chassis. The air shroud fits behind the two blowers.
Checking the Server Airflow
1.
Make sure there are no objects to obstruct airflow in and out of the server. In
addition, if you are using a front bezel, make sure the bezel's filter is replaced
periodically.
2. Do not operate the server without drives or drive trays in the drive bays. Use
only recommended server parts.
3.
Make sure no wires or foreign objects obstruct air flow through the chassis.
Pull all excess cabling out of the airflow path or use shorter cables.
4. The control panel LEDs inform you of system status. See “Chapter 3: System
Interface” for details on the LEDs and the control panel buttons.
Installation Complete
In most cases, the chassis power supply and system air blowers are pre-installed.
In the unlikely event that it is necessary to replace the blowers or power supply,
continue to the following section where general maintenance procedures will be
addressed. If the chassis will be installed into a rack, proceed to the next chapter
for rack installation instructions.
General Maintenance
The following section provides general maintenance information for the SC811
chassis