47
Chapter 2: Installation
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Power Fail LED
Pin Definitions (JF1)
Pin# Definition
5
3.3V
6
PWR Supply Fail
UID LED
NIC1 Active LED
HDD LED
PWR LED
3.3V Stby
3.3V Stby
Ground
3.3V Stby
1
2
Ground
Power Fail LED
NIC2 Active LED
3.3V
3.3V
OH/PWR Fail/Fan Fail LED
Power Button
Reset Button
1
2
Information LED-UID/OH/PWR Fail/Fan Fail LED
Pin Definitions (Pin 7 & Pin 8 of JF1)
Status
Description
Solid red
An overheat condition has occurred. (This may be caused by cable congestion).
Blinking red (1Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25Hz)
Power failure: check for a non-operational power supply
Solid blue
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Blinking blue (300 msec)
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
OH/Fan Fail/PWR Fail/UID LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel (JF1) to use UID/Overheat/
Fan Fail/Power Fail LED connections. The LED on pin 8 provides warnings of overheat, power
failure or fan failure. Refer to the tables below for details.
1. Power Fail LED
2. UID/OH/PWR Fail/Fan Fail LED