32
Chapter 3: Maintenance and Component Installation
4. Slide the replacement drive into the backplane socket and push it down onto the
mounting bracket until it clicks into position.
Note:
numbers above indicate the logical drive locations (drive map).
Figure 3-4. Replacing HDDs
3.5" HDD
Latch
Backplanes
1
9
8
7
6
5
4
3
2
10
12
11
Hard Drive Carrier LED Indicators
LED Color State
Status
Activity LED
Blue
Off
SATA drive installed or empty bay
Blue
Solid On
SAS drive installed
Blue
Blinking
I/O activity
Status LED
Red
Solid On
Failed drive for SAS/SATA with RSTe support
Red
Blinking at 1 Hz
Rebuild drive for SAS/SATA with RSTe support
Red
Blinking with two blinks and
one stop at 1 Hz
Hot spare for SAS/SATA with RSTe support
Red
On for five seconds, then off
Power on for SAS/SATA with RSTe support
Red
Blinking at 4 Hz
Identify drive for SAS/SATA with RSTe support