SuperServer 6019P-WT/WTR User's Manual
22
Figure 2-2. Installing the Server into a Rack
Note:
Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.
Installing to a Telco Rack
To install the SuperServer 6019P-WT/WTR into a Telco (or “open”) type rack, use two
L-shaped brackets on either side of the chassis (four total).
1. First, determine how far the server will extend out from the front of the rack. The chassis
should be positioned so that the weight is balanced between front and back.
2. Attach the two front brackets to each side of the chassis, then the two rear brackets
positioned with just enough space to accommodate the width of the rack.
3. Finish by sliding the chassis into the rack and tightening the brackets to the rack. See
Figure 2-3.
Slide rail mounted equipment is not to be used as a shelf or a work space.