128
SuperServer 2029BT-DNR/DNC0R User's Manual
Power Supply
Model: PWS-2K22A-1R, 80 Plus Titaniam level
Rated Output Power: 1200W/1800W/1980W/2090/2200W
Rated AC Input Voltages: Output Power, +12 V Output Current
100-127 Vac: 1200 W, 100 A
220-220 Vac: 1800 W, 150 A
220-230 Vac: 1980 W, 165 A
230-240 Vac: 2090 W, 174 A
180-220 Vac (UL/cUL only): 2090 W, 174 A
220-240 Vac (UL/cUL only): 2200 W, 183 A
230-240 Vac (CCC only): 2200 W, 174 A
Rated Input Frequency: 50-60 Hz
12 V standby: 2.1 A max
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11)
Other: VCCI-CISPR 32 and AS/NZS CISPR 32
Environmental: Directive 2011/65/EU and Delegated Directive (EU) 2015/863 and Directive 2012/19/EU
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See