6-2
A+ SERVER 1042G-TF User's Manual
Figure 6-1. Chassis: Front and Rear Views
6-2 Control
Panel
The control panel (located on the front of the chassis) must be connected to the
JF1 connector on the serverboard to provide you with system status indications. A
ribbon cable has bundled these wires together to simplify the connection. Connect
the cable from JF1 on the serverboard to the appropriate header on the Control
Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both
connectors. Pull all excess cabling out of the airfl ow path.
The control panel LEDs inform you of system status. See "Chapter 3: System
Interface" for details on the LEDs and the control panel buttons. Details on JF1 can
be found in "Chapter 5: Advanced Serverboard Installation."
6-3 System
Cooling
Four 4-cm counter-rotating fans provide the cooling for the system. Each fan unit
is actually made up of two fans joined back-to-back, which rotate in opposite
directions. This counter-rotating action generates exceptional airfl ow and works to
dampen vibration levels.
It is very important that the chassis top cover is properly installed and making a
good seal in order for the cooling air to circulate properly through the chassis and
cool the components. See Figure 6-2 for details.
Control Panel
Hot-Swap Drive Bays (3)
Power Supply
PCI Slot
COM
Port
USB
Ports
LAN
Ports
VGA
Port
Dedicated IPMI
LAN Port
PS2 Keyboard/
Mouse Ports
Summary of Contents for Supero A+ SERVER 1042G-TF
Page 1: ...SUPER USER S MANUAL Revision 1 0d A SERVER 1042G TF...
Page 5: ...v Preface Notes...
Page 14: ...1 6 A SERVER 1042G TF User s Manual Notes...
Page 30: ...3 4 A SERVER 1042G TF User s Manual Notes...
Page 67: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 3 Removing a Hard Drive Carrier 1 1 1 2...
Page 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Installing the Air Shroud 4 1 4 1 5...