Chapter 5: Chassis Setup and Maintenance
Figure 5-14: Chassis Fans
(shown with optional fan installed)
The SC815 Chassis includes four pre-installed fans. One or two extra slots are
available so that. additional fans may be added.
Replacing a System Fan
If necessary, open the chassis while the power is running to determine which
fan has failed. Never run the server for an extended period of time with the
chassis open.
Turn off the power to the system and unplug the system from the outlet.
Remove the failed fan's power cord from the serverboard.
Lift the failed fan from the chassis and pull it completely out from the
serverboard.
Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
Reconnect the fan wires to the exact same chassis fan headers as the previ-
ous fan.
Power up the system and check that the fan is working properly before re-
placing the chassis cover.
1.
2.
3.
4.
5.
6.
7.