5-4 Rack Mounting Instructions
This section provides information on installing the SC113M chassis into a rack unit
with the rails provided. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. You should also refer to the instal-
lation instructions that came with the rack unit you are using.
Note:
This rail will fit a rack between 26" and 33.5" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections: an inner rail and an outer rail.
Inner Rails
The inner rail comes preinstalled on the chassis and no assembly is required.
Figure 5-1. Inner Rails
Inner Rails
(Inner rail is preinstalled)
Locking Tabs
Both chassis rails have a locking tab. The tabs lock the server into place when
installed and pushed fully into the rack. These tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Rail Locking Tabs
Warning: do not pick up the server by the front handles. They are designed
to pull the system from a rack only.