Figure 1-1. Control Panel
1.3 Chassis Features
Control Panel
Power switches and status LEDs are located on the control panel on the front of the chassis.
Control Panel Features
Item
Features
Description
1
UID button
The unit identification (UID) button turns on or off the UID LED on the rear of the
chassis. This is useful for locating the server in a large rack environment.
2
Information LED
Alerts operator to several states, as noted in the table below.
3
NIC LED
Indicates network activity on LAN2 when flashing.
4
NIC LED
Indicates network activity on LAN1 when flashing.
5
HDD
Indicates hard drive activity when flashing.
6
Power LED
Indicates power is being supplied to the system power supply units. This
LED is illuminated when the system is operating normally.
7
Reset button
The hardware reset button is used to reboot the system if needed.
8
Power button
The main power switch applies or removes primary power from the power supply to
the server but maintains standby power.
1
4
5
6
7
8
3
2
Information LED
Color, Status
Description
Red, solid
An overheat condition has occurred.
Red, blinking at 1Hz
Fan failure, check for an inoperative fan.
Red, blinking at 0.25Hz
Power failure, check for a non-operational power
supply.
Red, solid, with Power LED blinking
green
Fault detected
Blue and red, blinking at 10 Hz
Recovery mode
Blue, solid
UID has been activated locally to locate the
server in a rack environment.
Blue, blinking at 1Hz
UID has been activated using the BMC/IPMI to
locate the server in a rack environment.
Also functions as a BMC reset?