Chapter 4: BIOS
79
SMBIOS Event Log Standard Settings
Log System Boot Event
This feature toggles the System Boot Event logging to enabled or disabled. The options are
Disabled
or Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurrences that
a duplicate event must happen before the MECI counter is incremented. This is a numeric
value. The default value is
1
.
METW
The Multiple Event Time Window (METW) defines the number of minutes that must pass
between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99.
The default value is
60
.
Custom Options
Log EFI Status Code
Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error Codes or
Progress Codes. The options are
Enabled
and Disabled.
Convert EFI Status Code to Standard Smbios Type
This feature allows the user to enable or disable the conversion of EFI Status Codes to
Standard SMbios Types. The options are
Disabled
and Enabled.
Note:
After making changes on a setting, be sure to reboot the system for the changes
to take effect.
View Smbios Event Log
This feature displays a list of logged Smbios events.