Chapter 6: UEFI BIOS
77
Console Redirection Settings
Out-of-Band Mgmt Port
The feature selects a serial port in a client server to be used by the Microsoft Windows
Emergency Management Services (EMS) to communicate with a remote host server. The
options are
COM1,
COM2 (Disabled), and AMT SOL.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection.
Select VT100 to use the ASCII character set. Select VT100+ to add color and function
key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use
UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100,
VT100+,
VT-UTF8
, and
ANSI.
Bits per Second
This item sets the transmission speed for a serial port used in Console Redirection. Make
sure that the same speed is used in the host computer and the client computer. A lower
transmission speed may be required for long and busy lines. The options are 9600, 19200,
57600, and
115200
(bits per second).
Flow Control
Use this item to set the flow control for Console Redirection to prevent data loss caused
by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer
is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The
options are
None,
Hardware RTS/CTS, and Software Xon/Xoff.
Data Bits
Parity
Stop Bits
PCIe/PCI/PnP Configuration
This menu provides PCIe/PCI/PnP configuration settings and information.
PCI Bus Driver Version
Above 4G Decoding
This setting
Enables
or Disables 64-bit capable devices ability to be decoded in above 4G
address space (only if the system supports 64-bit PCI decoding).