Chapter 3: Maintenance and Component Installation
Figure 3-19. Installing the Rear 2.5" Hard Drive Cage
Installing the Rear 2.5" Hard Drive--SC216B Only
The SC216BTS model chassis supports an optional hard drive cage for two additional 2.5"
hot-swappable hard drives. The hard drive cage installs in the rear of the chassis next to
the power supply. Once the hard drive cage has been installed, the 2.5" hard drives may be
removed without powering down the server.
Installing the 2.5" Rear Hard Drive Cage
1.
Power down the system as described in Section 3.1, lay the chassis on a flat, stable
surface and remove the chassis cover as described in Section 3.2.
2. Orient the rear hard drive cage as shown (Figure 3-19), aligning the opening at the end
of the cage with the opening at the back of the chassis.
Figure 3-18. Drive Bays: Logical Configuration
0
23
11
2
2