2-4

Super AOC-URG4N4-b2XT Add-on Card User's Guide

2-5   Jumpers

Explanation of Jumpers

To modify the operation of the add-on card, a jumper can be used to choose between 
optional settings. A jumper creates shorts between two pins to change the function 
of the connector. See the add-on card layouts on page 2-1 for the jumper locations.

Note:

 On two-pin jumpers, "Closed" means the jumper is on and "Open" 

means the jumper is off the pins. 

3.3V Standby Power Enable

The 3.3V Standby Power Enable jumper is located at JP3 on the add-on card. Refer 
to the layouts on page 2-1 for the locations of the jumper. To turn 3.3V Standby on, 
connect pins 1-2 to enable the NC-SI/BMC management-shared LAN as well as the 
WoL during standby. Switch to pins 3-4 to disable those functions when you want 

to turn 3.3V Standby off. The default setting is 

3.3V Standby Off

Summary of Contents for AOC-URG4N4-b2XT

Page 1: ...User s Guide Revision 1 0 AOC URG4N4 b2XT ...

Page 2: ...VE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any dispu...

Page 3: ...u have received may or may not look exactly the same as the graphics shown in this user s guide Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered You can obtain service by calling your ven dor for a Returned Merchandise Authorization RMA number When returning the motherboard to the manufactu...

Page 4: ...stallation and to prevent damage to the system or injury to yourself Warning Important information is given to ensure proper system installa tion or to prevent damage to the components or injury to yourself Note Additional information is given to differentiate between various mod els or provides information for the correct system setup Naming Convention ...

Page 5: ...t RMA supermicro com RMA Support Webmaster supermicro com Webmaster Website www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email Sales_Europe supermicro com Sales Inquiries Support_Europe supermicro Technical Support RMA_Europe supermicro RMA Support Website www supermicro nl Asia Pacifi...

Page 6: ...C URG4N4 b2XT Add on Card User s Guide Asia Pacific Email Sales Asia supermicro com tw Sales Inquiries Support supermicro com tw Technical Support RMA supermicro com tw RMA Support Website www supermicro com tw ...

Page 7: ...r 2 Hardware Components 2 1 Add On Card Image and Layout 2 1 2 2 Major Components 2 2 2 3 Ports 2 3 2 4 Connectors 2 3 2 5 Jumpers 2 4 Installation 3 1 Static Sensitive Devices 3 1 3 2 Before Installation 3 2 3 3 Installing the Add on Card 3 2 3 4 Installing Drivers for Windows 3 3 3 5 Installing Drivers for Broadcom BCM57416 3 4 Preface ...

Page 8: ...support and updates please refer to our website at http www supermicro com products nfo networking cfm adapter 1 2 Key Features The key features of this add on card include the following 1U Networking Ultra Riser card for 1U Ultra systems Dual 10GbE RJ45 ports Broadcom BCM57416 Ethernet Controller One internal PCI E 4 0 x16 slot Four NVMe ports two Slim SAS x8 Low latency RDMA over Converged Ether...

Page 9: ... NVMe ports two Slim SAS x8 Networking Features Jumbo Frames up to 9600 byte 802 3x flow control Link Aggregation 802 3ad Virtual LANs 802 1q VLAN tagging Configurable Flow Acceleration CFA IEEE 1588 and Time Sync RDMA over Converged Ethernet RoCE TruFlow Technology Stateless Offload Features TCP UDP IPv4 IPv6 checksum offload Large Send Offload LSO Receive Segment Coalescing RSC TCP Segmentation ...

Page 10: ...ual Functions VXLAN NVGRE Geneve Edge Virtual Bridging EVB Flow Processing Exact Wildcard Match Flow Lookup VLAN insertion deletion Data Center Bridging Priority based Flow Control PFC IEEE 802 1Qbb Enhanced Transmission Selection ETS IEEE802 1Qau Quantized Congestion Notification QCN IEEE802 1Qau Data Center Bridging Capability eXchange DCBX IEEE802 1Qaz Eight traffic classes per port fully DCB c...

Page 11: ...I compliant power management PCI Express Active State Power Management ASPM Ultra low power mode Pass through Energy Efficient Ethernet IEEE802 3az 2010 Power Consumption Maximum power consumption 16W Operating Conditions Storage temperature 40 C to 70 C 40 F to 158 F Storage humidity 90 non condensing relative humidity at 35 C Supported Platforms Supermicro Ultra systems ...

Page 12: ...rview 1 5 Add on Cards Controller Network Ports Supported Speeds Connector Types PCI E Slot NVMe Ports AOC URG4N4 b2XT Broadcom BCM57416 2 10GbE 2x RJ45 One PCI E 4 0 x16 internal 4 2x Slim SAS x8 1 4 Available SKUs ...

Page 13: ... JP3 SLOT1 PCI E Gen4 x16 SXB3_3 Broadcom BCM57416 Controller JRJ45 Chapter 2 Hardware Components 2 1 Add On Card Image and Layout AOC URG4N4 b2XT Image AOC URG4N4 b2XT Top Layout 3 1 2 4 REV 1 01 AOC URG4N4 b2XT DESIGNED IN USA SLIMSAS2 SLIMSAS1 SXB3_2 SXB3_1 AOC URG4N4 b2XT Bottom Layout 6 5 ...

Page 14: ...alled on AOC URG4N4 b2XT AOC URG4N4 b2XT Major Components No Component Name Definition 1 Broadcom BCM57416 Ethernet LAN controllers 2 JP3 Jumper Setting 1 2 3 3V Standby On 3 4 3 3V Standby Off Default 3 JRJ45 Dual RJ45 Ports 4 SlimSAS1 NVMe Cable Connector 5 SlimSAS2 NVMe Cable Connector 6 Slot 1 PCI E Gen4 x16 ...

Page 15: ...ge 2 1 for the locations of the ports Note For further explanation on how to connect SlimSAS cables from the card to the backplane please refer to the section of the correspond ing motherboard system s user manual that details the complete system configuration If the system user manual does not mention them then that system does not use SlimSAS1 and SlimSAS2 2 4 Connectors RJ45 Port LEDs For more ...

Page 16: ...per locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins 3 3V Standby Power Enable The 3 3V Standby Power Enable jumper is located at JP3 on the add on card Refer to the layouts on page 2 1 for the locations of the jumper To turn 3 3V Standby on connect pins 1 2 to enable the NC SI BMC management shared LAN as well as the WoL during standby Swit...

Page 17: ... by its edges only do not touch its components or peripheral chips Put the add on card back into the antistatic bags when not in use For grounding purposes make sure that your system chassis provides excel lent conductivity between the power supply the case the mounting fasteners and the add on card Unpacking The add on card is shipped in antistatic packaging to avoid static damage When unpacking ...

Page 18: ... latest updates and hotfixes 3 3 Installing the Add on Card Follow the steps below to install the add on card into your system 1 Remove the server cover and if necessary set aside any screws for later use 2 Remove the add on card slot cover If the case requires a screw place the screw aside for later use 3 Position the add on card in the slot directly over the connector and gently push down on bot...

Page 19: ...Run the CDR NIC If you do not have a product CD ROM download drivers from the Supermicro Support Website and then transfer them to your system 2 When the SUPERMICRO window appears click on the computer icon next to the product model Note If the FOUND NEW HARDWARE WIZARD screen displays on your system click CANCEL 3 Click on INSTALL DRIVERS AND SOFTWARE 4 Follow the prompts to complete the installa...

Page 20: ...s infiniband diags perftest qperf librdmacm utils yum y install groupinstall InfiniBand Support 2 From the CDR NIC LAN driver CD or FTP site go to the following directory Broadcom 10G Linux_Driver 3 Download the Linux driver package file netxtreme bnxt_en ver tar gz 4 Install the driver by entering the following commands tar xzvf nextreme bnxt_en ver tar gz cd nextreme bnxt_en ver make build make ...

Page 21: ... Drivers Use the following procedures to install drivers on the Windows operating system Installing 10G Drivers for the Windows Operating System 1 From the CDR NIC LAN driver CD or FTP site go to the following directory Broadcom 10G Windows 2 Choose the desired Windows driver package folder 3 Drivers are in inf format You can install the driver from Device Manager ...

Page 22: ... expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous ap plications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions...

Reviews: