Chapter 6: Advanced Chassis Setup
6-13
6-9 Node
Installation/Removal
As with any server system, power must be removed from the serverboard
when upgrading or installing memory or processors. In the 2U Twin server, the
serverboards (nodes) are capable of being hot-swapped from the chassis, allowing
one to be powered down for servicing while the other continues operating.
Caution!
Removing a node from the server affects the airfl ow throughout the system.
For this reason, nodes should be removed, serviced and replaced as quickly as
possible. Also note that powering down a node will power down all the hard drives
that are logically associated with it.
Removing a Node (Figure 6-12)
1. Depress the power button on the control panel to power down the node.
2. There are two latches located below the handles at the rear of the node tray.
Push both of these inward.
3. While pushing the latches inward, grasp both handles and pull the node from
the chassis.
4. Perform any service needed to the node in a timely manner.
5. Reinstall the node by pushing it into its bay until fi rmly seated.
Summary of Contents for 6027TR-D71FRF SUPERSERVER SUPERO
Page 1: ...SUPER SUPERSERVER Revision 1 0 SUPERSERVER 6027TR D71RF 6027TR D71QRF 6027TR D71FRF...
Page 5: ...v SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER Notes...
Page 10: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER x Notes...
Page 30: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL 3 4 Notes...
Page 50: ...4 20 SUPERSERVER 6027TR D71QRF D71FRF D71RF User s Manual Notes...
Page 85: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 128: ...7 28 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...
Page 130: ...A 2 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...