Chapter 2: Server Installation
2-7
3. Slide the inner rails into the outer rails, keeping the pressure even on both
sides. When the chassis has been pushed completely into the rack, it should
click into the locked position.
4. Optional screws may be used to secure the to hold the front of the chassis to
the rack.
2-6 Checking the Serverboard Setup
After you install the SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF in the rack,
you will need to open the unit to make sure the serverboard is properly installed
and all the connections have been made.
Accessing the inside of the System
Before operating the server for the fi rst time, it is important to remove the protective
fi lm covering the top of the chassis, in order to allow for proper ventilation and
cooling.
Removing the Chassis Cover and Protective Film
1. Remove the two screws which secure the top cover onto the chassis as
shown above.
2. Lift the top cover up and off the chassis.
3. Peel off the protective fi lm covering the top cover and the top of the chassis
4. Check that all ventilation openings on the top cover and the top of the chassis
are clear and unobstructed.
Checking the Components and Setup
1. You may have one or two processors already installed into the serverboard.
Each processor needs its own heat sink. See Chapter 5 for instructions on
processor and heat sink installation.
2. Your SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF server system may
have come with system memory already installed. Make sure all DIMMs
are fully seated in their slots. For details on adding system memory, refer to
Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. Also make sure that no cables are positioned in front of
the fans. See Chapter 5 for details on cable connections.
Summary of Contents for 6027TR-D71FRF SUPERSERVER SUPERO
Page 1: ...SUPER SUPERSERVER Revision 1 0 SUPERSERVER 6027TR D71RF 6027TR D71QRF 6027TR D71FRF...
Page 5: ...v SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER Notes...
Page 10: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER x Notes...
Page 30: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL 3 4 Notes...
Page 50: ...4 20 SUPERSERVER 6027TR D71QRF D71FRF D71RF User s Manual Notes...
Page 85: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 128: ...7 28 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...
Page 130: ...A 2 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...