![Supermicro 1029U-TRTP User Manual Download Page 124](http://html1.mh-extra.com/html/supermicro/1029u-trtp/1029u-trtp_user-manual_1404326124.webp)
SuperServer 1029U-T Series User's Manual
124
When Log is Full
Select Erase Immediately for all messages to be automatically erased from the event log
when the event log memory is full. The options are
Do Nothing
and Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are
Enabled and
Disabled
.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurrences that
a duplicate event must happen before the MECI counter is incremented. This is a numeric
value. The default value is
1
.
METW
The Multiple Event Time Window (METW) defines number of minutes must pass between
duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default
value is
60
.
Note
: After making changes on a setting, be sure to reboot the system for the changes
to take effect.
View SMBIOS Event Log
This section displays the contents of the SMBIOS Event Log.