2-6
S
UPER
S
ERVER 1027R-73DAF User's Manual
Outer Rails
Installing the Outer Rails to the Rack (Figures 2-3 and 2-4)
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
fi ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the left outer rail.
Secure to the
Front of the Rack
Secure to the
Rear of the Rack
Figure 2-3. Assembling the Outer Rails
Attach Outer Racks
Together