Superior VRT43PFWS Installation And Operation Instructions Manual Download Page 9

www.SuperiorFireplaces.US.com

126706-01A

9

  CAUTION:  Log  appliances 

installed  in  this  firebox  create 

warm air currents. These currents 

move heat to wall surfaces next 

to firebox. Installing firebox next 

to vinyl or cloth wall coverings or 

operating firebox where impuri-

ties (such as, but not limited to, to-

bacco smoke, aromatic candles, 

cleaning  fluids,  oil  or  kerosene 

lamps, etc.) in the air exist, may 

discolor walls or cause odors.

IMPORTANT:

 Vent-free gas log appliances 

add moisture to the air. Although this is benefi-

cial, installing firebox in rooms without enough 

ventilation air may cause mildew to form from 

too much moisture. See 

Air for Combustion 

and Ventilation

, page 6.

IMPORTANT:

 Make sure the firebox is level. 

If  firebox  is  not  level,  log  set  will  not  work 

properly.

Note: Your Vanguard firebox is designed to 

be used in zero clearance installations. Wall 

or framing material can be placed against any 

exterior surface on the rear, sides or top of 

your firebox, except where standoff spacers 

are integrally attached. If standoff spacers 

are attached to your firebox, these spacers 

can be placed directly against wall or fram-

ing materials.

Use dimensions shown for rough openings to 

create the easiest installation (see 

Built-In or 

Internal Wall Firebox Installation

, page 9).

INSTALLATION CLEARANCES

 WARNING: Maintain the 

minimum clearances. If you can, 

provide greater clearances from 

floor, ceiling and adjoining wall.

Carefully follow the instructions below. This 

will ensure safe installation.

Minimum Wall and Ceiling Clearances

A.  Clearances from edge of liner to any 

combustible wall should not be less than 

8" (see Figure 5).

B.  Clearances from top of firebox opening to 

the ceiling should not be less than 42".

INSTALLATION

Continued

C.  When the firebox is installed on carpet-

ing or other combustible material, other 

than wood flooring, the firebox should be 

installed on a metal or wood panel extend-

ing the full width and depth of enclosure.

D.  Clearances from the bottom of firebox to 

the floor is 0".

E.  Clearances from open end of firebox to fac-

ing wall shall should not be less than 36".

 CAUTION: Do not install fire-

box directly on carpet or vinyl.

 CAUTION: Use only the clear-

ances specified in this manual or 

on the firebox rating plate.

Minimum clearances to combustibles are:

•  Sides of outer casing 

0" min.

•  Drywall to sides and top of 

0" min.

   front face

•  Ceiling to opening 

42' min.

•  Floor (see 

Minimum Wall

 

0" min.

 

and Ceiling Clearances

, note C)

•  Perpendicular walls  

4' min.

  Right and Left

•  Distance to Facing Walls 

36" min.

  on Sides and End of Firebox

Figure 5 - Minimum Clearance Front View 

42" Min.

0" to Wood

Floor

8" Min.

4"

Min.

0" Min. Clearance to Upper Frame/Wallboard

Ceiling

 

Edge of
Brick Liner

4" Min. from the Perpendicular
Side Wall to the Edge of Facia

1/2" Min. Clearance
to Combustibles

43 

3

/

4

"

24"

 

36" Minimum
from Edge of
Facial to
Facing Wall
on Open End
of Firebox

Figure 6 - Minimum Clearance - Top View

Summary of Contents for VRT43PFWS

Page 1: ...ed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any othe...

Page 2: ...erns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting SAFETY This appliance may be installed in an aftermarket permanently located manufactured...

Page 3: ...could cause pilot outage 12 Do not use the firebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place 13 Provide adequate clearances...

Page 4: ...r where you bought firebox 3 Check appliance for any shipping damage If appliance is damaged call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts before returning to dealer NOTICE T...

Page 5: ...firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 9 2 Everything needed to complete installation 3 This model CANNOT be installed in a bedroom or bathroo...

Page 6: ...ws may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually tight construction is defined as co...

Page 7: ...s and vents to the outdoors Example Gas water appliance ___________ Btu Hr Gas firebox logs __________ Btu Hr Total __________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 40 000 39 000 79 000...

Page 8: ...ithin 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include at tics and crawl spaces Follow the National Fue...

Page 9: ...u can provide greater clearances from floor ceiling and adjoining wall Carefully follow the instructions below This will ensure safe installation Minimum Wall and Ceiling Clearances A Clearances from...

Page 10: ...lt in installation of this firebox involves installing firebox into a framed in enclosure This makes the front of firebox flush with wall If installing a mantel above the firebox you must follow the c...

Page 11: ...the louvered slots on the front of the firebox WARNING Use only non combustible mortar or adhe siveswhenoverlappingthefront facing with noncombustible facing material WARNING Do not fill the spaces ar...

Page 12: ...54 may be run from the regulator to the incoming 1 2 NPT black iron gas line You may also route the incoming 1 2 NPT black iron gas line directly to the appliance regulator Remove the gas line cover...

Page 13: ...pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing manual shut off valve during any pressure testing of the gas supply piping system a...

Page 14: ...irculating air passageways of the appliance be kept clean WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burnsorclothingignition Young...

Page 15: ...functioning purchase date Usually we will ask you to return the part to the factory TECHNICAL SERVICE You may have further questions about installa tion operation or troubleshooting If so contact INNO...

Page 16: ...ces US com 126706 01A 16 PARTS MODEL VRT43PFWS These items are used on both sides of fireplace 8 15 17 17 17 7 1 7 2 7 3 2 17 11 17 17 12 6 16 13 10 5 17 17 15 16 4 16 16 6 16 15 17 17 18 Typ Typ Typ...

Page 17: ...p Spacer 4 5 26731 Deflector Hood 2 6 26740 Nailing Flange 12 7 1 02013 Side Refractory Brick Liner 1 7 2 02014 Bottom Refractory Brick Liner 1 7 3 02036 Bottom Refractory Brick Liner 1 8 24007 Side R...

Page 18: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Page 19: ...EP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________...

Page 20: ...126706 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126706 01...

Reviews: