Superior VRT43PFWS Installation And Operation Instructions Manual Download Page 13

www.SuperiorFireplaces.US.com

126706-01A

13

Prepare  incoming  black  iron  gas  line  with 

Teflon tape or pipe joint compound (check with 

local codes as to the use of Teflon tape). Com-

pounds used on threaded joints of gas piping 

shall be resistant to the action of propane/LP 

and should be applied lightly to ensure excess 

sealant does not enter the gas line.
Complete your gas installation by connecting 

the incoming gas line to the appliance regula-

tor. Secure all joints tightly with wrench but do 

not overtighten. If a flexible gas line is used, 

take care not to kink the connector.

 WARNING: All gas piping 

and connections must be tested 

for leaks after the installation is 

completed. After ensuring that 

the manual shutoff gas valve is 

open, apply a soap and water 

solution to all connections and 

joints. If bubbles appear, leaks 

can be detected and corrected. 

DO NOT USE OPEN FLAME FOR 

LEAK  TESTING  AND  DO  NOT 

OPERATE ANY APPLIANCE  IF 

A LEAK IS DETECTED.

INSTALLATION

Continued

GAS SUPPLY TESTING

Note: This section is intended as a guide for 

qualified  technicians  installing  gas  to  this 

vent-free firebox.

  CAUTION:  Do  not  connect 

vent-free appliance before pres-

sure testing gas piping. Damage 

to gas valve may result and an 

unsafe condition may be caused.

The appliance and its’ individual shutoff valve 

must be disconnected from the gas supply 

piping system during any pressure testing of 

that system at test pressures in excess of 1/2 

psig (3.5 kPa).
The appliance must be isolated from the gas 

supply piping system by closing manual shut-

off valve during any pressure testing of the gas 

supply piping system at test pressures equal 

to or less than 1/2 psig (3.5 kPa).

Figure 15 - Locating Electrical 

Connection and Gas Connection on 

Either Side of Fireplace

HARD-WIRING FIREBOX

This model can be hard-wired to the duplex 

outlet  located  inside  the  firebox  bottom  if 

desired. This allows the blower accessory to 

be plugged into the duplex outlet.

NOTICE: A qualified electrician 

must connect electrical wiring to 

duplex outlet for built-in instal-

lation. Follow all local codes. In 

absence of local codes follow 

The National Electric Code ANS/

NFPA 70.

ELECTRICAL INSTALLATION

A model GA3500A blower system assembly 

is available for use with the vent-free firebox 

as  an  optional  accessory.  This  blower  is 

designed to be installed on either side of 

the firebox, when provisions for a 120 VAC 

supply connection are made at either end 

of the cabinet. Use of a blower system other 

than those manufactured by INNOVATIVE 

HEARTH PRODUCTS voids the warranty.
Electrical  connections  are  made  within  the 

receptacle with wires that are routed through 

the bushing provided (see Figure 15). The re-

ceptacle may be relocated to either side, when 

necessary. However, the cover plate must be 

replaced over the unused access point. Be 

certain to properly ground the vent-free firebox 

using the green grounding wire.

Note: A 120V supply connection to the leads 

Cover 

Plates

Electrical 

Connection 

Access Hole

Gas Connection 

Access Hole

Summary of Contents for VRT43PFWS

Page 1: ...ed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any othe...

Page 2: ...erns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting SAFETY This appliance may be installed in an aftermarket permanently located manufactured...

Page 3: ...could cause pilot outage 12 Do not use the firebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place 13 Provide adequate clearances...

Page 4: ...r where you bought firebox 3 Check appliance for any shipping damage If appliance is damaged call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts before returning to dealer NOTICE T...

Page 5: ...firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 9 2 Everything needed to complete installation 3 This model CANNOT be installed in a bedroom or bathroo...

Page 6: ...ws may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually tight construction is defined as co...

Page 7: ...s and vents to the outdoors Example Gas water appliance ___________ Btu Hr Gas firebox logs __________ Btu Hr Total __________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 40 000 39 000 79 000...

Page 8: ...ithin 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include at tics and crawl spaces Follow the National Fue...

Page 9: ...u can provide greater clearances from floor ceiling and adjoining wall Carefully follow the instructions below This will ensure safe installation Minimum Wall and Ceiling Clearances A Clearances from...

Page 10: ...lt in installation of this firebox involves installing firebox into a framed in enclosure This makes the front of firebox flush with wall If installing a mantel above the firebox you must follow the c...

Page 11: ...the louvered slots on the front of the firebox WARNING Use only non combustible mortar or adhe siveswhenoverlappingthefront facing with noncombustible facing material WARNING Do not fill the spaces ar...

Page 12: ...54 may be run from the regulator to the incoming 1 2 NPT black iron gas line You may also route the incoming 1 2 NPT black iron gas line directly to the appliance regulator Remove the gas line cover...

Page 13: ...pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing manual shut off valve during any pressure testing of the gas supply piping system a...

Page 14: ...irculating air passageways of the appliance be kept clean WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burnsorclothingignition Young...

Page 15: ...functioning purchase date Usually we will ask you to return the part to the factory TECHNICAL SERVICE You may have further questions about installa tion operation or troubleshooting If so contact INNO...

Page 16: ...ces US com 126706 01A 16 PARTS MODEL VRT43PFWS These items are used on both sides of fireplace 8 15 17 17 17 7 1 7 2 7 3 2 17 11 17 17 12 6 16 13 10 5 17 17 15 16 4 16 16 6 16 15 17 17 18 Typ Typ Typ...

Page 17: ...p Spacer 4 5 26731 Deflector Hood 2 6 26740 Nailing Flange 12 7 1 02013 Side Refractory Brick Liner 1 7 2 02014 Bottom Refractory Brick Liner 1 7 3 02036 Bottom Refractory Brick Liner 1 8 24007 Side R...

Page 18: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Page 19: ...EP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________...

Page 20: ...126706 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126706 01...