1.  Do not use this firebox as a wood burning fireplace. Use only 

decorative unvented room heaters (log sets).

2.  Do not add extra logs or ornaments such as pine cones, vermiculite 

or rock wool. Using these added items can cause sooting.

3.  Use only the provided hood. See Parts, page 17.
4.  Vent-free gas log heaters installed in these  fireboxes require 

fresh air ventilation to run properly. See Air for Combustion and 

Ventilation, page 7.

5.  Do not run vent-free heaters installed in these fireboxes

• where flammable liquids or vapors are used or stored
• under dusty conditions

6.  Do not use this firebox to cook food or burn paper or other objects.
7.  Turn unit off and let cool before servicing. Only a qualified service 

person should service and repair firebox.

8.  Operating vent-free heaters installed in these fireboxes above 

elevations of 4,500 feet could cause pilot outage.

9.  Do not use the firebox if it has been under water.
10. Before using furniture polish, wax, carpet cleaner or similar 

products, turn heater off. If heated, the vapors from these 

products may create a white powder residue within burner box 

or on adjacent walls and furniture.

11. Provide adequate clearances around air openings.

LOCAL CODES

Install and use firebox with care. Follow all local codes. In the absence 

of local codes, use the latest edition of The National Fuel Gas Code 

ANSI Z223.1/NFPA 54*. Firebox must be electrically grounded in 

accordance with the National Electrical Code, ANSI/NFPA70 (latest 

edition).
*Available from:

American National Standards Institute, Inc.

25 West 43rd Street, 4th floor

New York, NY 10036

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA 02169-7471

PRODUCT FEATURES

OPERATION

This firebox is designed for use with approved ANSI Z21.11.2 deco-

rative type unvented room heaters. (Physical size limitations apply. 

Refer to minimum firebox requirements supplied with log heater.) 

It requires no outside venting or chimney making installation easy 

and inexpensive.

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS

These appliances are approved for installation in the US state of 

Massachusetts if the following additional requirements are met:

•  Un-vented Room Heaters shall be installed in accordance with 

527 CMR 30.

•  Installation and repair must be done by a plumber or gas fitter 

licensed in the Commonwealth of Massachusetts.

•  The flexible gas line connector used shall not exceed 36 inches 

(92 centimeters) in length.

•  The individual manual shut-off must be a T-handle type valve.
•  Unvented appliances may NOT be installed in bedrooms or 

bathrooms.

•  A working smoke detector must be installed in the area where 

vent-free appliances are installed.

Seller of unvented propane or natural gas-fired supplemental room 

heaters shall provide to each purchaser a copy of 527 CMR 30 upon 
sale of the unit.

LOCATING FIREBOX

PLANNING

Plan where you will install the firebox. This will save time and money 

later when you install the firebox. Before installation, consider the 
following:
1.  Where firebox will be located. Allow for wall and ceiling clearances 

(see Installation Clearances, page 9).

2.  Everything needed to complete installation.
3.  These models CANNOT be installed in a bedroom unless maximum 

Btu rating of installed vent-free log set is less than 10,000 Btu/hr.

4.  Proper air for combustion and ventilation (page 7).

OUTDOOR ENCLOSURE REQUIREMENTS
Must conform to one of the following conditions:

•  With walls on all sides, but with no overhead cover;
•  Within a partial enclosure which includes an overhead cover and 

no more than two side walls. These side walls may be parallel, 

as in breezeway or at right angles to each side; or

•  Within a partial enclosure which includes an overhead cover 

and three sidewalls, as long as 30% or more of the horizontal 

periphery of the enclosure is permanently open.

Summary of Contents for VRE6036

Page 1: ...In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or accessory items when needed Keep it with...

Page 2: ...ING Anychangetothisfireboxoritscontrols can be dangerous WARNING Do not allow fans to blow directly into the firebox Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts th...

Page 3: ...ve type unvented room heaters Physical size limitations apply Refer to minimum firebox requirements supplied with log heater It requires no outside venting or chimney making installation easy and inex...

Page 4: ...ces us com 901010 00_C 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 VRE6036 36 HEARTH 29 30 1 2 30 36 54 3 4 11 1 8 45 1 4 36 3 8 35 1 4 22 1 2 9 1 2 3 3 8 7 3 8 11 1 8 20 1 4 Ref 1 1 4 19 50 1 8 3 3 4...

Page 5: ...s com 901010 00_C 5 PRODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 VRE6042 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 51 1 4 7 42 13 50 1 8 54 3...

Page 6: ...s com 901010 00_C 6 Figure 3 VRE6050 21 3 4 1 1 4 8 3 4 9 1 2 3 3 8 13 50 1 8 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 4 54 3 4 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODUCT SPECIFICATIONS...

Page 7: ...fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Firebox Location Confined and Unconfined Space...

Page 8: ...AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one wit...

Page 9: ...ttom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use t...

Page 10: ...low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acceptable height remove the ma...

Page 11: ...es This firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or...

Page 12: ...and Leading Brick panels Hearth Panel Side leading brick Panel 3 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the...

Page 13: ...l to avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints...

Page 14: ...rnace cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decorative gas appliance incorporating an...

Page 15: ...r or dealer Parts will be shipped at prevailing prices at time of order CAT NO MODEL DESCRIPTION OPTIONAL AIR KITS F1091 AK4F Outside Air Kit For Floor Installation F1094 AK4 Outside Air Kit For Sidew...

Page 16: ...SuperiorFireplaces us com 901010 00_C 16 11 10 11 13 14 15 16 14 3 20 20 21 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS 36 42 AND 50 MODELS...

Page 17: ...12 J5329 BRACKET F P HANDLE 4 13 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 14 J6934 COVER GAS CONDUIT PLATE 36E 4 15 J4368 GAS CONDUIT ONE 2 16 J4369 GAS CONDUIT TWO 2 17 HEAT SHIELD SUPPORT 1 18 FIREBO...

Page 18: ...0342 Mosaic42WRFS Masonry 42 Warm Red Full Stacked F0343 Mosaic42WRSS Masonry 42 Warm Red Split Stacked F0346 Mosaic42WRFH Masonry 42 Warm Red Herr Full F0347 Mosaic42WRSH Masonry 42 Warm Red Herr Spl...

Page 19: ...ned to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could resul...

Page 20: ...ealer name P901010 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...