background image

SuperiorFireplaces.US.com

127029-01D

9

INSTALLATION

 WARNING: A qualifi ed service person must install 

fi rebox. Follow all local codes.

 WARNING: Never install fi rebox

• in a bedroom or bathroom*
• in a recreational vehicle
• where curtains, furniture, clothing, or other fl am-

mable objects are less than 36" from front or 42" 
from top of fi rebox; for side clearances see 

Figure 6

• in high traffi c areas
• in windy or drafty areas
* Unless installed log set is rated at 10,000 Btu/Hr or 
less, 6,000 for bathrooms

 CAUTION: Log heaters installed in this fi rebox cre-

ate warm air currents. These currents move heat to 
wall surfaces next to fi rebox. Installing fi rebox next to 
vinyl or cloth wall coverings or operating fi rebox where 
impurities (such as, but not limited to, tobacco smoke, 
aromatic candles, cleaning fl uids, oil or kerosene lamps, 
etc.) in the air exist, may discolor walls or cause odors.

NOTICE: The fi rebox identifi cation label (including 
model number, serial number, clearances, etc.) is 
located on a chain under the bottom refractory.

IMPORTANT:

 Vent-free gas log heaters add moisture to the air. Al-

though this is benefi cial, installing fi rebox in rooms without enough 
ventilation air may cause mildew to form from too much moisture. 
See, 

Page 7

.

IMPORTANT:

 Make sure the fi rebox is level. If fi rebox is not level, log 

set will not work properly.

NOTE:

 Your fi rebox is designed to be used in zero clearance instal-

lations. Wall or framing material can be placed against any exterior 
surface on the rear, sides, top or bottom of your fi rebox, except 
where standoff spacers are integrally attached. If standoff spacers 
are attached to your fi rebox, these spacers can be placed directly 
against wall or framing materials. Use the dimensions shown for 
rough opening to create the easiest installation.
Use dimensions shown for rough openings to create the easiest 
installation 

(see Built-In Firebox Installation, 

Page 10

).

INSTALLATION CLEARANCES

 WARNING: Maintain the minimum clearances. If 

you can, provide greater clearances from fl oor, ceil-
ing, and adjoining wall.

Carefully follow the instructions below. This will ensure safe instal-
lation.

Minimum Wall and Ceiling Clearances 

(see Figure 6)

A.

  Clearances from the side of the fi replace cabinet to any combus-

tible material and wall should follow diagram in 

Figure 6

.

 

Example: The face of a mantel, bookshelf, etc. is made of combus-
tible material and protrudes 3-1/2" from the wall. This combustible 
material must be 4" from the side of the fi replace cabinet 

(see 

Figure 4, Page 8

).

B.

  Clearances from the top of the fi rebox opening to the ceiling should 

not be less than 42".

C.

  When fi rebox is installed on carpeting, tile (vinyl) or other com-

bustible material, other than wood fl ooring, the fi rebox should be 
installed on a metal or wood panel extending the full width and 
depth of the enclosure.

D.

  Clearances from the bottom of fi rebox to the fl oor is 0".

These fi reboxes can be installed as freestanding units against a 
wall with approved cabinet mantels that may be available from your 
retailer or supplier, or as a built-in unit. The clearances are the same 
for either installation method.

Figure 6 - Minimum Clearance for Combustible to Wall

*Minimum 16" from Side Wall 

Example

*

Summary of Contents for VRE4536WH

Page 1: ...US C Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Page 2: ...y or death from burns fire explosion electrical shock and carbon monoxide poisoning You must operate this fireplace with the provided fireplace screen and hood in place Make sure these parts are in pl...

Page 3: ...ter It requires no outside venting or chimney making installation easy and inexpensive COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Mass...

Page 4: ...D 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRE4536RS VRE4536WS VRE4536RH and VRE4536WH 20 1 4 Ref 1 1 4 22 1 2 19 36 HEARTH 29 30 1 2 30 36 54 1 2 11 1 8 45 1 8 36 3 8 35 1 4 9 1 2 3 3 8...

Page 5: ...RODUCT SPECIFICATIONS continued 42 MODELS Figure 2 42 Models VRE4542RS VRE4542WS VRE4542RH and VRE4542WH 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 5...

Page 6: ...6 Figure 3 50 Models VRE4550RS VRE4550WS VRE4550RH and VRE4550WH 21 3 4 8 3 4 9 1 2 3 3 8 13 50 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 8 54 1 2 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODU...

Page 7: ...ebox Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z223 1 NFPA54 allows two meth ods for determining whether the space in which the heater is being installed is confined or un...

Page 8: ...ned space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces se...

Page 9: ...ottom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use...

Page 10: ...ational product standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acc...

Page 11: ...es This firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or...

Page 12: ...he right and left refractory panels with the gas line knock outs orientated down toward the bottom refractory Align the left and right panels with the rear panel so the grout lines line up 5 Install t...

Page 13: ...l furnace cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decorative gas appliance incorporatin...

Page 14: ...1 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS MODEL NO CAT NO INTERIOR VRE4536WS F0474 White Stacked VRE4536WH F0476 White Herringbone VRE4542WS F0478 White Stacked VRE4542WH F0480 White He...

Page 15: ...EPLACE 36 1 RP110454 02 TOP FIREPLACE 42 1 RP110454 01 TOP FIREPLACE 50 1 9 J6997 SPACER FIREPLACE TOP 42MC 4 10 FIREPLACE SURROUND ASSEMBLY 1 11 J4362 SPACER CLEARANCE 36 42 50 6 12 J5329 BRACKET F P...

Page 16: ...itute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 5 3 4 6 6 IMPORTANT Installation of brick panels should be done after the fireplace...

Page 17: ...ORY HEARTH 36 STD WHITE 1 REFRACTORY HEARTH 42 STK WHITE 1 REFRACTORY HEARTH 50 STK WHITE 1 3 REFRACTORY RIGHT 36 STK WHITE 1 REFRACTORY RIGHT 36 HER WHITE 1 REFRACTORY RT 42 STK WHITE 1 REFRACTORY RT...

Page 18: ...yed ignition fireplace will not produce specified heat for propane LP unit propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SE...

Page 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Page 20: ...ributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 127029 01 Rev D 01 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 SuperiorFireplaces US com Record the...