3

Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the heater and
have it serviced by a qualified professional, as
it may not be operating correctly.

• Due to high temperatures, the heater should
be located out of traffic and away from furniture
and draperies.

• Children and adults should be alerted to the
hazard of high surface temperatures and should
stay away to avoid burns or clothing ignition.

• Young children should be carefully super-
vised when they are in the same room with
the heater.

• Do not place clothing or other flammable
material on or near the heater for the purpose
of drying.

• Installation and repair should be done by a
qualified service person. The heater should be
inspected before use and at least annually by a
professional service person. More frequent clean-
ing may be required due to excessive lint from
carpeting, bedding material, etc. It is important
that control compartments, burners and circulat-
ing air passageways of the heater be kept clean.

• Allow the heater to cool before servicing.
Always shut off any electricity or gas to the
heater while performing service work.

• Do not install the VF4000 series heaters in a
bedroom or bathroom.

• The installation must conform with local
codes or, in the absence of local codes with the
National Fuel Gas Code, ANSI Z223.1.

• The heater and its individual shut-off valve
must be disconnected from the gas supply
piping system while performing any tests of the
gas supply piping system at pressures in ex-
cess of 1/2 psig.

• Vent-Free appliances may NOT be installed in
bedrooms or bathrooms.

• A working smoke detector must be installed
in the area where vent-free appliances are
installed.

Seller of unvented propane or natural gas-
fired supplemental room heaters shall pro-
vide to each purchaser a copy of 527 CMR 30
upon sale of the unit.

New York:
These fireplaces are approved for installation
in the US state of New York, but not in New
York City.

COMBUSTION AND VENTILATION AIR

These heaters shall not be installed in a con-
fined space.  The heater may be located in
unusually tight construction provided the
space is unconfined, or if confined, is pro-
vided with two permanent openings commu-
nicating directly with an additional room(s)
of sufficient volume so that the combined
volume of all connected spaces meets the
criteria for an unconfined space, (National
Fuel Gas Code ANSI Z223.1 (latest edition),
Section 5.3).  Generally 50 ft

3

 per 1,000 BTU

input of all operating appliances in the space.

The National Fuel Gas Code defines a con-
fined space as a space whose volume is less
than 50 ft

3

 per 1,000 BTU/Hr (4.8 m

3

 per kw)

of the aggregate input rating of all appliances
installed in that space and an unconfined
space as a space whose volume is not less
than 50 ft

3

 per 1,000 BTU/Hr (4.8 m

3

 per kw)

of the aggregate input rating of all appliances
installed in that space. Rooms communicat-
ing directly with the space in which the appli-
ances are installed, through openings not
furnished with doors, are considered a part of
the unconfined space.

Unusually tight construction is defined as con-
struction where:

a. wall and ceilings exposed to the outside
atmosphere have a continuous water vapor
retarder with a rating or one perm or less with
openings gasketed or sealed, and

b. weather stripping has been added on oper-
able windows and doors, and

c. caulking or sealants are applied to areas such
as joints around window and door frames,
between sole plates and floors, between wall-
ceiling joints, between wall panels, at penetra-
tions for plumbing, electrical, and gas lines,
and at other openings.

• The heater must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure test-
ing of the gas supply piping system at test
pressures equal to or less than 1/2 psig.

• Any safety screen or guard removed for
servicing the heater must be replaced prior to
operating the heater.

• Keep heater area clear and free from com-
bustible materials, gasoline and other flam-
mable vapors and liquids.

• Do not use these appliances if any part has
been under water.  Immediately call a qualified
professional service technician to inspect the
appliance and to replace any parts of the control
system and any gas control which have been
under water.

• Input ratings are shown in BTU per hour and
are for elevations up to 7,000 feet.  Operating
heater above elevations of 7,000 feet may cause
ODS pilot outage.

• Ensure that the heater is clean when operat-
ing. Excessive dust accumulation on the burner
and logs will increase the amount of carbon
monoxide formation and could lead to carbon
monoxide poisoning and death.

CODES

Adhere to all local codes or in their absence the
latest edition of The National Fuel Gas Code
ANSI Z223.1 or NFPA54 which can be obtained
from The American National Standards Insti-
tute, Inc. (1430 Broadway, New York, NY,
10018) or National Fire Protection Association,
Inc. (Batterymarch Park, Quincy, MA,  02269).

Massachusetts And New York Require-
ments

These appliances are approved for installation
in the following USA locations listed in the
following:

Massachusetts:
These fireplaces are approved for installation
in the US state of Massachusetts if the follow-
ing additional requirements are met-

• Installation and repair must be done by a
plumber or gas fitter licensed in the Common-
wealth of Massachusetts.

• The flexible gas line connector used shall not
exceed 36 inches (92 centimeters) in length.

• The individual manual shut-off must be a T-
handle type valve.

WARNING:  FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING
INSTRUCTIONS PROVIDED IN THIS
DOCUMENT WILL RESULT IN AN IM-
PROPERLY INSTALLED AND OPERAT-
ING UNVENTED ROOM HEATER, VOID-
ING ITS WARRANTY.  ANY CHANGE TO
THIS HEATER AND/OR ITS OPERATING
CONTROLS IS DANGEROUS.  IMPROPER
INSTALLATION OR USE OF THIS HEATER
CAN CAUSE SERIOUS INJURY OR DEATH
FORM FIRE, BURNS, EXPLOSION OR
CARBON MONOXIDE POISONING.

Summary of Contents for VF4000-CHN-2 and

Page 1: ...IREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATIONS This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and...

Page 2: ...e page 9 Optional Equipment page 10 Forced Air Kit page 10 Operation and Care page 11 Cleaning and Servicing page 11 Replacement Parts page 11 Accessories Components page 12 Appliance Specifications p...

Page 3: ...ft 3 per 1 000 BTU Hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicat ing directly with the space in which the appli ances are installed through...

Page 4: ...above these appliances should be positioned just above the appliance top spacers The minimum height from the base of the VF4000 to the underside of com bustible materials used to construct a utility s...

Page 5: ...Thefollowingstepsrepresentthenormal sequence of installation Each installation is unique however and might require a different sequence CAUTION HEATERSCREATEWARMAIRCUR RENTS THESE CURRENTS MOVE HEAT...

Page 6: ...canresultincorrosionovertime Never use an open flame to check for leaks Figure 4 37 940mm 15 1 2 394mm Outside Wall Back Wall of Chase Enclosure Including Finishing Materials If Any Figure 5 37 940mm...

Page 7: ...gure 12 ensuring that the polarity as determined by the colors of the wires is exactly as shown The black and red wire loop must be left intact with the mating connectors connected Figure 10 VF4000 CM...

Page 8: ...hejunctionbox cover plate Failure to do so will prevent the appliance from operating The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the Nat...

Page 9: ...d 16 Note Instructions are also found on the pull out panel located on the bottom surface of the appliance Figure 16 Figure 18 Standard Manual Version Shown After setting the logs into position as des...

Page 10: ...ive illustrations The appliances covered in this manual are heater rated and produce a great deal of heat Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater op...

Page 11: ...it should be installed along with the appliance Refer to Figure 11 andStep5fordetailedinstallationinstructions Rocker Switch Kit An optional rocker switch kit can be installed directly on VF4000 CMN P...

Page 12: ...as Flex Line Kit FFGC Refractory Liner Kit VF5RLK Decorative Volcanic Stone FDVS Wood Surround Wall SUR 5PW Wood Surround Corner SUR 5PC Brass Louver Kit BRLK 5C BSK 5 Brass Surround Kit BRLK CS Squar...

Page 13: ...940 mm 36 914 mm 30 762 mm 31 1 2 800 mm 15 381 mm Front View Left Side View Right Side View Opposite Gas Line Opening J Box Opening 8 203 mm 3 3 4 95 mm 3 1 2 89 mm Top View 27 686 mm 36 914 mm 15 1...

Page 14: ...e failure detector from shutting off the gas while the probe is warming up 10 Release the control knob while turning counterclockwise to the HI or LOW Position If the knob does not pop out when releas...

Page 15: ...E DIAGRAMS ILLUSTRATION NOT TO SCALE 15 Figure 22 Pilot Location Figure 23 Pilot Turn Control Knob to OFF Position Figure 24 Turn Control Knob to IGN Position O F F I G N L O W H I O F F I G N L O W H...

Page 16: ...STOP Read the safety information above on this page 2 Access left side louver 3 Turn remote wall switch to OFF 4 Verify main line shut off valve is open 5 Push in gas control knob slightly and turn c...

Page 17: ...orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation SFC recommends running the heater with excess ventilation for the first few hours Turn control knob to LO...

Page 18: ...0345 1 110344 1 Pilot Propane LPG 110341 1 901915 1 4 Regulator Natural 110351 1 903218 1 Regulator Propane LPG 110352 1 112081 1 5 Front Burner 110281 1 110281 1 6 Rear Burner Natural 113301 1 113301...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS 9 10 15 14 4 7 6 5 12 1 12 13 13 2 8 3 CH Models CM Models CH Models CM Models SIT Valve Shown 11...

Page 20: ...03590 REV N 12 2007 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult...

Reviews: