SuperiorFireplaces.us.com
126857-01B
18
1. STOP! Read the safety information on
Page 17
.
2. Make sure equipment shutoff valve is ful ly
open.
3. Set selector switch in the OFF po si tion.
4. Press in and turn control knob clock wise
to the OFF position see
Figure 17
.
WARNING: Burners will
come on automatically within
one minute when the selector
switch is in the ON position after
the pilot is lit.
5. Wait
fi ve (5) minutes to clear out any gas.
Then smell for gas, in clud ing near the
fl oor. If you smell gas, STOP! Fol low “B”
in the safety information,
Page 17
. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob coun ter-
clock wise
to the PILOT po si tion.
Press in control knob for fi ve (5) seconds
see
Figure 17
.
NOTE: You may be running this heat er
for the fi rst time after hook ing up to gas
supply. If so, the con trol knob may need
to be pressed in for 30 sec onds or more.
This will allow air to bleed from the gas
system
.
7. With control knob pressed in, press igniter
button. This will light pilot. The pilot is at-
tached to the front burner. If needed, keep
press ing igniter button until pilot lights.
NOTE: If pilot does not stay lit, con tact a
qualifi ed service person or gas sup pli er for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Man u al Light ing Procedure, Page 19
.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified ser vice
person or gas supplier for re pairs.
NOTE: If pilot goes out, repeat steps 4
through 8
.
OPERATION
Continued
9. Slightly push in and turn control knob
counterclockwise
to the ON posi-
tion.
10. Wait one minute and switch selector
switch to the ON po si tion to light burners.
11. Set fl ame adjustment knob to any lev el
be tween HI and LO.
12. To leave pilot lit and shut off burners only,
turn control knob clockwise to the PILOT
position, use remote control manual OFF
button, then set selector switch in the OFF
position.
WARNING: Make sure
selector switch is in to OFF
position when you are away
from home for long periods
of time. Appliance will come
on automatically with selector
switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the
OFF po si tion.
2a. Set selector switch in the OFF po si tion.
2b. When using the Hand-Held Re mote: Set
selector switch in the OFF po si tion to
pre vent drain ing battery.
3. Close equipment shut off valve
(see Figure
14, Page 16).
Figure 17 - Control Knob and Igniter
Button Locations
LO
IH
O
F
F
PI
LOT O
N
AUTO
OFF
ON
Control Knob
Igniter Button
Flame Adjustment Knob
Selector Switch
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.