Superior VCT2036B Installation And Operation Instructions Manual Download Page 3

You must operate this fireplace 

with  the  provided  fireplace 

screen,  hood  if  provided,  in 

place.  Make  sure  these  parts 

are  in  place  and  screens  are 

closed before running firebox. 

The supplied hood may not be 

replaced with a hood which may 

be provided with a log heater.

Keep the fireplace area clear and 

free from combustible materials, 

gasoline  and  other  flammable 

vapors and liquids.

1.  Do not use this firebox as a wood-burning 

fireplace. Use only decorative unvented 

room heaters (log sets).

2.  Do not add extra logs or ornaments such as 

pine cones, vermiculite or rock wool. Using 

these added items can cause sooting.

SAFETY

Continued

3.  Use only the provided hood or appropri-

ate hood accessory. See 

Accessories

 on 

page 17.

4.  Vent-free gas log heaters installed in these 

fireboxes require fresh air ventilation to 

run properly. See 

Air for Combustion and 

Ventilation,

 page 6.

5.  Do not run firebox

• where flammable liquids or vapors are 

used or stored

• under dusty conditions

6.  Do not use this firebox to cook food or 

burn paper or other objects.

7.  Turn firebox off and let cool before servic-

ing. Only a qualified service person should 

service and repair firebox.

8.  Operating  firebox  above  elevations  of 

4,500 feet could cause pilot outage.

9.  Do not use firebox if it has been under water 

due to shock hazard that could result with 

the blower accessary (if installed) in place.

LOCAL CODES

Install  and  use  heater  with  care.  Follow  all 

local codes. In the absence of local codes, 

use the latest edition of 

The National Fuel Gas 

Code, ANSI Z223.1/NFPA 54*

. Firebox must 

be electrically grounded in accordance with 

the 

National Electrical Code, ANSI/NFPA70

 

(latest edition).
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

State of Massachusetts:

 The installation 

must be made by a licensed plumber or 

gas  fitter  in  the  Commonwealth  of  Mas-

sachusetts.
Sellers of unvented propane or natural 

gas-fired supplemental room heaters shall 

provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.

Vent-free  gas  products  are  prohibited  for 

bedroom and bathroom installation in the 

Commonwealth of Massachusetts.

PRODUCT FEATURES

OPERATION

This firebox is designed for use with approved 

ANSI Z21.11.2 decorative type unvented room 

heaters. (Physical size limitations apply. Refer 

to  minimum  firebox  requirements  supplied 

with log heater.) It requires no outside vent-

ing or chimney making installation easy and 

inexpensive. When used without the blower, 

the  firebox  requires  no  electricity  making  it 

ideal for emergency backup heat.

OUTSIDE AIR KIT ACCESSORY

The optional AK4 and AK4F air kit provides ad

-

ditional outdoor air to improve burner efficiency 

and reduce build-up of condensation in living 

space. Follow instructions included with air kit.

REFRACTORY BRICK LINER 

Your firebox may feature a concrete refractory 

brick liner. As with all concrete liners, this liner 

may develop slight cracks when exposed to 

heat. These cracks will not affect the perfor-

mance of the fireplace or vent-free gas logs.

OPTIONAL FIBER LINERS

For a vintage look, the fiber panels give a old 

masonry brick look and are light weight and 

easy to install. 

Summary of Contents for VCT2036B

Page 1: ...ult causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GA...

Page 2: ...lowsurfacetocool before touching Carefully supervise young chil dren when they are in the room with firebox WARNING Improper instal lation adjustment alteration service or maintenance can causeinjuryo...

Page 3: ...ANSI Z223 1 NFPA 54 Firebox must be electrically grounded in accordance with the National Electrical Code ANSI NFPA70 latest edition Available from American National Standards Institute Inc 1430 Broad...

Page 4: ...the following 1 Where the firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 9 PRODUCT SPECIFICATIONS Figure 1 Firebox Dimensions 36 Models Right Side Vie...

Page 5: ...307 9 227 9 705 8 193 12 933 3 628 7 330 9 705 8 163 26 504 24 926 21 041 4 392 7 763 28 612 Figure 2 Firebox Dimensions 42 Models Right Side View Right Side View Firebox Top View Front View Outside...

Page 6: ...s communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating...

Page 7: ...ir from the outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free heater _________ Btu Hr Total _________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compar...

Page 8: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the att...

Page 9: ...eplace cabinet see Figure 5 B Clearances from the top of firebox opening to ceiling should not be less than 42 C When firebox is installed on carpeting or other combustible material other than wood fl...

Page 10: ...crews through holes in nailing flange see Figure 7 6 If using an optional perimeter trim kit install the trim after final finishing and or painting of wall See instructions included with trim accessor...

Page 11: ...nock Out One Hole Gas Line Hole Equipment Shutoff Valves Install One INSTALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS WARNING A qualified ser vicepersonmustinstallfirebox Follow all local codes Thi...

Page 12: ...e power source wiring through electri cal bushing opening and electrical cover plate and make all necessary connec tions 3 Slide all wiring connections in electrical housing as shown in Figure 11 page...

Page 13: ...ing out DO NOT FORCE The panels are actually held in place by means of a retention dimple embossed on the edge of removable panels Accessibility to the bottom on 36 and 42 models only can also be gain...

Page 14: ...no foreign objects in blower wheel Also double check all wire leads and make sure wire routing is not pinched or in a precarious position Correct ac cordingly CAUTION Use gloves as sheet metal parts m...

Page 15: ...ouch a blowerwheelwhileinoperation 5 Turn on power to duplex outlet if previ ously turned off per warning in column 2 page 13 6 Plug in blower power cord to duplex outlet see Figure 13 page 13 7 Turn...

Page 16: ...Wall Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing in a Vented Crawl Space Screws Hood INSTALLING FIREPLACE HOOD AND SCREEN 1 Attach hood to firebox using screw...

Page 17: ...NOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced und...

Page 18: ...www SuperiorFireplaces US com 126715 01A 18 PARTS MODELS VRT2036B VCT2036B VRT2036WS VCT2036WS VRT2042B VCT2042B VRT2042WS AND VCT2042WS 1 3 4 2 5 5 11 13 12 7 7 6 9 10 8...

Page 19: ...hite Stack 1 7 20027 Refractory Bracket 2 8 20280 Top Spacer 4 9 107128 01 Conduit Gas 4 10 110037 01 Electrical Duct Assembly 1 11 21198 Plate Blower Access 1 12 21171 Cover Gas Conduit 3 21171 Cover...

Page 20: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Page 21: ...ted on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep recei...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...126715 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126715 01...