Superior VCT2036B Installation And Operation Instructions Manual Download Page 10

www.SuperiorFireplaces.US.com

126715-01A

10

(36'') 66 

7

/

8

"

(42'') 72 

7

/

8

"

(36'') 47 

3

/

8

"

(42'') 52 

1

/

2

"

INSTALLATION

Continued

BUILT-IN FIREBOX INSTALLATION

Built-in  installation  of  this  firebox  involves 

installing firebox into a framed-in enclosure. 

This makes the front of firebox flush with wall. 

Optional brass trim accessories are available 

(see 

Accessories, 

page 17). The brass trim 

will extend past sides of firebox approximately 

1/2". This will cover the rough edges of the 

wall opening. If installing a mantel above the 

firebox, you must follow the clearances shown 

in Figure 6. Follow the instructions below to 

install the firebox in this manner.

1.  Frame in rough opening. The firebox 

framing should be constructed of 2 x 4 

lumber or heavier. Use dimensions in the 

table and rough opening layout in Figure 

7a. Adjust framing so that firebox flushes 

with finished wall surface. If installing in a 

corner, use dimensions in Figures 7b for 

rough opening.

2.  Install gas piping to firebox location. See 

Installing Gas Line,

 page 11 and 

Con-

necting to Gas Supply 

in log set owner’s 

manual.

3.  Carefully set firebox in front of rough open-

ing with back of firebox inside wall open-

ing.

 

IMPORTANT: 

If installing a perimeter 

trim  kit,  see  instructions  included  with 

trim accessory. You must install shoulder 

screws from trim kit now.

4. 

Carefully insert firebox into rough opening.

5.  Attach  firebox  to  wall  studs  using  nails 

or wood screws through holes in nailing 

flange (see Figure 7).

6.  If using an optional perimeter trim kit, 

install the trim after final finishing and/or 

painting of wall. See instructions included 

with trim accessory for attaching trim.

7.  Install and properly test gas log heater. 

Follow  installation  instructions  included 

with the vent-free gas log heater that is 

being installed.

IMPORTANT: 

When  finishing  your  firebox, 

combustible  materials  such  as  wall  board, 

gypsum board, sheet rock, drywall, plywood, 

etc. may be butted up next to the sides and top 

of the firebox. Combustible materials should 

never overlap the firebox front facing.

Figure 6 - Minimum Mantel Clearances 

for Built-In Installation

Rough Opening Dimensions for 

Built-in Installation

Model

Front Width

(Inside to Inside)

Height

Depth

(Min.)

36"

38 

1

/

4

"

37 

5

/

8

"

22"

42"

44 

1

/

4

"

37 

5

/

8

"

22"

Figure 7 - Rough Opening for Installing 

in Wall

Depth

(Minimum)

Width

(Inside to Inside)

Height 

Figure 

7a

Figure 

7b

Supplied

Firebox Hood

Must Be Used

at All Times

Wire-mesh

Screen

Firebox

Noncombustible

Material May

Project Off this

Surface above

the Firebox Hood

Mantel Shelf

Note: Any portion of the

mantel shelf must NOT

extend beyond this profile.

12" 16" 20"

1

/

2

"

3

/

4

"

12"

Note: All vertical

measurements are

from top of fireplace

hood opening to

bottom of mantel shelf.

These minimum

clearances replace any

other recommended

clearances supplied

with your ANSI Z21.11.2

approved gas logs.

Wall board or facing

material (above

firebox) may be of

combustible material,

including decorative

mantel ornaments or

other similar projec-

tions off of the facing

material.

Framing

Material

Summary of Contents for VCT2036B

Page 1: ...ult causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GA...

Page 2: ...lowsurfacetocool before touching Carefully supervise young chil dren when they are in the room with firebox WARNING Improper instal lation adjustment alteration service or maintenance can causeinjuryo...

Page 3: ...ANSI Z223 1 NFPA 54 Firebox must be electrically grounded in accordance with the National Electrical Code ANSI NFPA70 latest edition Available from American National Standards Institute Inc 1430 Broad...

Page 4: ...the following 1 Where the firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 9 PRODUCT SPECIFICATIONS Figure 1 Firebox Dimensions 36 Models Right Side Vie...

Page 5: ...307 9 227 9 705 8 193 12 933 3 628 7 330 9 705 8 163 26 504 24 926 21 041 4 392 7 763 28 612 Figure 2 Firebox Dimensions 42 Models Right Side View Right Side View Firebox Top View Front View Outside...

Page 6: ...s communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating...

Page 7: ...ir from the outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free heater _________ Btu Hr Total _________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compar...

Page 8: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the att...

Page 9: ...eplace cabinet see Figure 5 B Clearances from the top of firebox opening to ceiling should not be less than 42 C When firebox is installed on carpeting or other combustible material other than wood fl...

Page 10: ...crews through holes in nailing flange see Figure 7 6 If using an optional perimeter trim kit install the trim after final finishing and or painting of wall See instructions included with trim accessor...

Page 11: ...nock Out One Hole Gas Line Hole Equipment Shutoff Valves Install One INSTALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS WARNING A qualified ser vicepersonmustinstallfirebox Follow all local codes Thi...

Page 12: ...e power source wiring through electri cal bushing opening and electrical cover plate and make all necessary connec tions 3 Slide all wiring connections in electrical housing as shown in Figure 11 page...

Page 13: ...ing out DO NOT FORCE The panels are actually held in place by means of a retention dimple embossed on the edge of removable panels Accessibility to the bottom on 36 and 42 models only can also be gain...

Page 14: ...no foreign objects in blower wheel Also double check all wire leads and make sure wire routing is not pinched or in a precarious position Correct ac cordingly CAUTION Use gloves as sheet metal parts m...

Page 15: ...ouch a blowerwheelwhileinoperation 5 Turn on power to duplex outlet if previ ously turned off per warning in column 2 page 13 6 Plug in blower power cord to duplex outlet see Figure 13 page 13 7 Turn...

Page 16: ...Wall Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing in a Vented Crawl Space Screws Hood INSTALLING FIREPLACE HOOD AND SCREEN 1 Attach hood to firebox using screw...

Page 17: ...NOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced und...

Page 18: ...www SuperiorFireplaces US com 126715 01A 18 PARTS MODELS VRT2036B VCT2036B VRT2036WS VCT2036WS VRT2042B VCT2042B VRT2042WS AND VCT2042WS 1 3 4 2 5 5 11 13 12 7 7 6 9 10 8...

Page 19: ...hite Stack 1 7 20027 Refractory Bracket 2 8 20280 Top Spacer 4 9 107128 01 Conduit Gas 4 10 110037 01 Electrical Duct Assembly 1 11 21198 Plate Blower Access 1 12 21171 Cover Gas Conduit 3 21171 Cover...

Page 20: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Page 21: ...ted on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep recei...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...126715 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126715 01...

Reviews: