background image

24

Touch-Up Paint Kit

70K99

TSPK-B

Touch-Up Paint, Metallic Black (12 oz aerosol)

PA I N T

Wall

Thermostat

Remote 

Control

Controls

Cat. No.

Model

Description

70005

RT-AC

Remote Thermostat AC   

(ref. form #775280M)

H0251

RCL-STAT

Remote Control, RCL-STAT, Deluxe 

Thermostat DC   

(ref. form #750129M)

H4635

DWTK

Wall Thermostat, Digital

75273

GASINS-RSCP-B  Round Black On/Off Switch Cover Plate

Gas Conversion Kits

H5464

MED-CK-NG to LP

Conversion Kit NG to LP  

(ref. form #775246M)

H5465

MED-CK-LP to NG

Conversion Kit LP to NG  

(ref. form #775237M)

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Cat. No.

 Description

H6033

Cassette Assembly, NG (if LP, also requires H5464 

conversion kit)

H6010

Main Burner Assembly

H5922

Pilot Assembly, Convertible NG or LP

H5938

Gas Control Valve, NG (if LP, also requires H5941 

regulator kit)

H5939

Regulator, NG

H5941

Regulator, LP

H5965

Orifice, Main Burner, NG #41

H5964

Orifice, Main Burner, LP #53

H6013

Blower w/Mounting Bracket

H5875

Blower Snap Switch

H5655

Blower Speed Control (rheostat)

H5744

On/Off Switch

H6007

On/Off Switch Wires

H5745

Piezo Igniter

H4635

Wall Thermostat, Digital

H5660

Power Cord 

(ref. form #506033-04)

H5977

Blower Wire

H5730

Speed Control Wire (for rheostat)

H5869

Log Set

H5863

Bag of Embers (volcanic stone)

H5864

Bag of Rockwool

H5990

Firebox Door w/Glass

H5989

Hardware Package

H5839

Log Set Support

REPLACEMENT PARTS - MODEL SDVI

ACCESSORIES

Finish Panels / Front Supports

75264

MED-ZC-SPPT "ZC Lower Finish Panel/Trad Face 

Support, * Requires Trim Piece below"   

(ref. form #775257M)

75251

GFHKET-B

Extended Side Trim Kit, Black   

(ref. form #775208M)

       WARNING 

Failure to position the parts in accordance with these 

diagrams  or  failure  to  use  only  parts  specifically 

approved with this appliance may result in property 

damage or personal injury.

       AVERTISSEMENT 

Risque de dommages ou de blessures si les pièces 

ne sont pas installées conformément à ces schémas 

et ou si des pièces autres que celles spécifiquement 

approuvées avec cet appareil sont utilisées.

Contact an Authorized Lennox Hearth Products dealer to obtain any of 

these parts. Never use substitute materials. Use of non-approved parts 

can result in poor performance and safety hazards.

Summary of Contents for SDVI and operation

Page 1: ...ment o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des inc...

Page 2: ...ibles 9 Insert Leveling 9 Installation 10 12 Venting Installation 10 Zero Clearance Fireplace Installation 11 Log Set Installation 11 Surround Panels Installation 12 Face Installation 12 Gas Line Inst...

Page 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Page 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Page 5: ...uel Gas Code and local zoning and code authorities for details on installation requirements Mobile home installations must conform with the Mobile Home Con struction and Safety Standard Title 24 CFR P...

Page 6: ...ess than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NEW YORK CITY NEW YORK MEA Certification Gas appliances must be tes...

Page 7: ...y Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and O...

Page 8: ...wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be drawnintotheheatcirculationblowerandbl...

Page 9: ...TO COMBUSTIBLES Minimum clearances include any projections such as shelves window sills mantels spacers standoffsorsurfacestocombustibleconstruction etc above the appliance Paint or lacquer used to fi...

Page 10: ...f an odor during the first hour of operation Venting Installation Your Superior gas insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223...

Page 11: ...iqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 37 5 mm 1 5 po peut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustio...

Page 12: ...ets on the surround brackets per instructions provided in decorative face kit C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounting Plates 4 Fasten top surround panel with the remaining t...

Page 13: ...ck the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient m...

Page 14: ...ILLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 14 Figure 15 SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Page 15: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Page 16: ...quipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the...

Page 17: ...aches operating temperature TO TURN OFF GAS TO APPLIANCE 1 Turn off the ON OFF rocker switch and or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service...

Page 18: ...he gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more th...

Page 19: ...ches to the insert for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions inc...

Page 20: ...EVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned a...

Page 21: ...lable from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CL...

Page 22: ...wer and then lift the panel with the blower attached out of the firebox To reinstall the blower repeat these steps in the reverse order Figure 21 Blower Wiring Schematic Green Ground Black Hot From Po...

Page 23: ...f pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot shoul...

Page 24: ...ontrol rheostat H5744 On Off Switch H6007 On Off Switch Wires H5745 Piezo Igniter H4635 Wall Thermostat Digital H5660 Power Cord ref form 506033 04 H5977 Blower Wire H5730 Speed Control Wire for rheos...

Page 25: ...are the part numbers of the instruction sheets included in kits Face Surround Panel Kits Required Includes Black Face Surround and Black Trim Cat No Model Description H7014 SDVI A B Arched Black Face...

Page 26: ...areil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU...

Page 27: ...agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO ce...

Page 28: ...ur other documents for future refer ence Product reference information We recommend that you record the following important information about your appliance Please contact your LHP dealer for any ques...

Reviews: