background image

SuperiorFireplaces.us.com

901008-00_NC

25

ACCESSORIES

BI-FOLD GLASS DOORS (For Use With Mosaic Brick Only)

CAT NO.

MODEL

DESCRIPTION

F1011

BDMO36E

GLASS DOOR, 36" EBONY

F1012

BDMO36G

GLASS DOOR, 36" PEWTER

F1013

BDMO36C

GLASS DOOR, 36" OILED BRONZE

F1014

BDMO42E

GLASS DOOR, 42" EBONY

F1015

BDMO42G

GLASS DOOR, 42" PEWTER

F1016

BDMO42C

GLASS DOOR, 42" OILED BRONZE

F1020

BDMO50E

GLASS DOOR, 50" EBONY

F1021

BDMO50G

GLASS DOOR, 50" PEWTER

F1022

BDMO50C

GLASS DOOR, 50" OILED BRONZE

BI-FOLD GLASS DOORS (For Use With Estate Refractory Panels Only

F1002

BDG36

GLASS DOOR, 36" BLACK

F1003

BDG36B

GLASS DOOR, 36" BRUSHED BRASS

F1004

BDG36P

GLASS DOOR, 36" PLATINUM

F1005

BDG42

GLASS DOOR, 42" BLACK

F1006

BDG42B

GLASS DOOR, 42" BRUSHED BRASS

F1007

BDG42P

GLASS DOOR, 42" PLATINUM

F1008

BD50

GLASS DOOR, 50" BLACK

F1009

BD50B

GLASS DOOR, 50" BRUSHED BRASS

F1010

BD50P

GLASS DOOR, 50" PLATINUM

DOUBLE WALL PIPE

   

F0932

12-12DM

12" Section Double Wall Pipe Snap Lock

F0933

18-12DM

18" Section Double Wall Pipe Snap Lock

F0934

24-12DM

24" Section Double Wall Pipe Snap Lock

F0935

36-12DM

36" Section Double Wall Pipe Snap Lock

F0936

48-12DM

48" Section Double Wall Pipe Snap Lock

F0953

12-12HT

12" Section Hi-Temp Double Wall Pipe Snap Lock

F0954

18-12HT

18" Section Hi-Temp Double Wall Pipe Snap Lock

F0955

24-12HT

24" Section Hi-Temp Double Wall Pipe Snap Lock

F0956

36-12HT

36" Section Hi-Temp Double Wall Pipe Snap Lock

F0957

48-12HT

48" Section Hi-Temp Double Wall Pipe Snap Lock

30° OFFSET AND RETURN

F0937

30E-12DM

30 Degree Offset and Return

F0958

30E-12HT

30 Degree Hi-Temp Offset and Return

OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION

F1091

AK4

Complete Outside Air Kit w/Collars Hood & 3' Flex

Summary of Contents for F4222

Page 1: ...1 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit...

Page 2: ...state this fireplace has been tested for use with this insert FOR YOUR SAFETY Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance Due...

Page 3: ...ing causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoison...

Page 4: ...mm 1 1 4 32 mm 20 1 4 515 mm Ref 14 1 2 369 mm 4 1 2 115 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 45 1 8 1159 mm 36 915 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 1550 mm 1...

Page 5: ...1 4 32 mm 23 585 mm Ref 21 3 4 553 mm 15 3 4 400 mm 4 3 8 112 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 51 1 8 1299 mm 42 1067 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 15...

Page 6: ...m 59 1 4 1505 mm 1 26 mm 11 280 mm 7 178 mm 67 1702 mm 61 1550 mm 58 1474 mm 49 1245 mm 30 762 mm 9 1 2 242 mm 10 1 2 267 mm 13 331 mm 50 1270 mm 34 3 8 874 mm 38 1 2 978 mm 28 1 2 724 mm 17 5 8 448 m...

Page 7: ...himney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 4 and 5 2 If fireplace is to be installed directly on carpeting tile or a...

Page 8: ...eplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be installed if desired see Figure 7...

Page 9: ...HT Pipe Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measured...

Page 10: ...outer pipe only see Figure 10 Do not penetrate the inner stainless Figure 11 Ceiling Support Pipe 12S 12DM Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See D...

Page 11: ...le FST10 is required to avoid intrusion by insu lation and recommended to negotiate a joist Firestop Thimble FST10 Figure 14a Firestop Thimble PENETRATING ROOF To maintain a 1 36 Models or 2 42 50 Mod...

Page 12: ...rm Collar Flashing FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many sh...

Page 13: ...d stacked at a vertical height difference of 18 see Figure 19 Note If a decorative shroud is to be installed contact the manufacturer for specifications 10 FOOT RULE All flue gas outlet chimney termin...

Page 14: ...talling Termination Cap 1 Noncombustible Spacer Note Do Not Seal Ventilation Openings 1 Space Chase Facia 1 4 Screen Chase Top Sheet Metal Screw Termination 36 915 mm Min 3 77 mm Min 2 51 mm Min 1 Spa...

Page 15: ...ey outlet see Figure 29 6 Attach storm collar where chimney pierces opening in flash ing Caulk where storm collar touches outer chimney pipe see Figure 29 Figure 26 Constructing Chase Top Flashing As...

Page 16: ...anels Hearth Panel Side leading brick Panel 4 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip on the top of the wall and screw into the inner...

Page 17: ...not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the direction of the joint Grout mixture in the joint...

Page 18: ...on for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace...

Page 19: ...ed gas log sets which have been found to comply with the standard for unvented room heaters ANSI Z21 11 2 are to be installed in this fireplace WARNING If the fireplace has been used for wood burning...

Page 20: ...ors ifleftpartlyopen maydraw gas and flame out of the fireplace opening creating risks of both fire and smoke WARNING Do not slam or strike doors Damage can result in a hazardous condition WARNING Dis...

Page 21: ...ntacting your dealer please have your model and serial numbers of your fireplace ready You can also visit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 22 to 24 for a complete...

Page 22: ...SuperiorFireplaces us com 901008 00_NC 22 PARTS MODELS 36 42 AND 50 1 20 19 5 6 7 10 9 11 12 13 16 17 15 14 8 23 22 3 24 18 2 21 4 MODEL CATALOG NO WRE6036 F4222 WRE6042 F4223 WRE6050 F4224...

Page 23: ...ACE TOP ASSEMBLY 42 1 FIREPLACE TOP ASSEMBLY 50 1 10 J6997 SPACER FIREPLACE TOP 42MC 4 11 FIREPLACE SURROUND ASSEMBLY 1 12 J4362 SPACER CLEARANCE 36 42 50 6 13 J5329 BRACKET F P HANDLE 4 14 J6900 PLAT...

Page 24: ...plit F0350 Mosaic50M2 Red Full Stacked F0351 Mosaic50M4 Red Split Stacked F0352 Mosaic50M2 Ivory Full Stacked F0353 Mosaic50M4 Ivory Split Stacked F0354 Mosaic50M3 Red Herr Full F0355 Mosaic50M5 Red H...

Page 25: ...S DOOR 42 PLATINUM F1008 BD50 GLASS DOOR 50 BLACK F1009 BD50B GLASS DOOR 50 BRUSHED BRASS F1010 BD50P GLASS DOOR 50 PLATINUM DOUBLE WALL PIPE F0932 12 12DM 12 Section Double Wall Pipe Snap Lock F0933...

Page 26: ...h Slip Section Pre Painted Black ROUND TOP TERMINATIONS F0947 RLT 12D Round Top Termination with Louvered Screen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F094...

Page 27: ...T Chimney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel...

Page 28: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Page 29: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 30: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 32: ...1008 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: