![Superior DRL6542TEN Installation And Operation Instructions Manual Download Page 17](http://html1.mh-extra.com/html/superior/drl6542ten/drl6542ten_installation-and-operation-instructions-manual_1402799017.webp)
Installation
900077-00, 07/2015
Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces
17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INSTALLATION SEQUENCE
The typical sequence of installation is outlined below; however, each installation is unique and may result in
variations to the steps described.
See the pages referenced in the following steps for detailed instructions.
Framing
1. Construct the Fireplace Framing
(
Page 17
).
2. Prepare the Fireplace Top Spacers
(
Page 19
).
3. Route the Gas Supply Line into the Fireplace
(
Page 19
).
4.
Rough in the Electrical Supply, if Needed
(
Page 20
).
5.
Place the Fireplace in the Framing, Secure,
and install Heat Shield
(
Page 43
).
Venting
6. Select a Horizontal or Vertical Vent System
(
Page 20
).
7.
Install the Vent Restrictor (if necessary)
(
Page 20
).
8. Install the Vent System
(
Page 24
).
Electrical Connection
9. Complete the Field Wiring
(
Page 35
).
10.
Optional: wire and Install the Power Vent
(
Page 37
).
Gas Connection
11. Connect the Gas Line
(
Page 37
).
12.
Install the wall Switch Receiver
(
Page 38
).
13. Initialize the Remote Control System
(
Page 44
).
14. Verify Proper Fireplace Operation
(
Page 38
).
Finishing
15. Install the Glass Media
(
Page 57
).
16. Install the baffle
(
Page 39
).
17. Install the Glass Door
(
Page 58
).
18. Adjust the Air Shutter to Ensure Proper Flame Appearance
(
Page 40
).
19. Install the Finishing Materials
(
Page 42
).
20. Install the bezel
, Barrier, and Optional Surroun
d
(
Page 42
).
21. Attach the Safety-in-Operation Warning Labels
(
Page 46
).
1.
Construct the Fireplace Framing
1.
Frame the fireplace as illustrated in
Table 10
. All framing details must allow for a minimum clearance to combustible
framing members as shown in
Table 8
. Steel studs are strongly recommended where exposed to heat.
2.
Mount the fireplace on a fully supported base extending the full width and depth of the unit. If installed on combustible
materials, such as carpeting, vinyl tile, or combustible material other than wood flooring, the appliance shall be
installed on a metal or wood panel extending the full width and depth of the fireplace.
NOTE:
Headers may be in direct contact with the fireplace top standoff spacers when they are bent up vertically,
maintaining the 9-3/8” clearance to the fireplace top, but must not be supported by them or notched to fit around them.
All construction above the fireplace must be self-supporting. DO NOT use the fireplace for structural support.