background image

20

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Printed in U.S.A. © 2002 by Lennox Hearth Products

P/N  725,001M  REV.  F  09/2005

The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.

LHP
1110 West Taft Avenue • Orange, CA  92865

REPLACEMENT PARTS

Model CDPF Shown - see table on page 18 and 19 for
replacement parts applicable to CDST, CDCR and CDCL

Firebox

Cabinet

1a

2a

3a

4a

8

10a

10b

37

13a

31

30

13b

44

16

12

12

7

17

14

1b

3b

4b

5

2b

11

32

33

34

36

35

40

43

41

45

42

6

15

9

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Summary of Contents for CDCL-CEN

Page 1: ...ement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L installationetservicedoit tr...

Page 2: ...d at the time of appliance installation The electronic appliances are designed to op erate on either natural or propane gas An electronic intermittent pilot system provides safe efficient operation Ex...

Page 3: ...eans an optional unit mounted ON OFF control switch Millivolt appliances only an optional wall mounted ON OFF con trol switch or an optional remote control The unit mounted ON OFF control switch may b...

Page 4: ...lower control compartment clean by vacuuming or brushing at least twice a year Morefrequentcleaningmayberequireddueto excessive lint from carpeting bedding materi als etc It is important that control...

Page 5: ...eanysurface build uponpilotandburnerassembly Cleanthe pilot nozzles ignitor flame rod and hood with a soft brush Ensure the pilot flame engulfs the flame sensor as shown Inspect the vent system at the...

Page 6: ...hutter opening must be adjustedbetweenthesetwoextremes Nosmoke orsootshouldbepresent Repositionthelogset if the flames impinge on any part of it If the log set is properly positioned and sooting condi...

Page 7: ...he burners to simulate ashes Maintain a in gap between the bottom of the horizontal grate section and the top of the pile of decorative volcanic stone Place a few dime sized pieces of the glowing embe...

Page 8: ...appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance Retain this manual File it with your other docu ments for future reference P...

Page 9: ...on the transmitterispressed asignallightilluminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all millivolt ignition systems as well as electronic ignitio...

Page 10: ...of view and is perfect for use in high volume areas such as lobbies and model homes where limited access to the appliance On Off switch is desirable This kit can be retrofitted to previously installed...

Page 11: ...top and bottom edges The DTK provides a touch of elegance to the appliance The door frame kit can be retrofitted onto previously installed appliances Louvers Kits Decorative louvers are available for...

Page 12: ...ntrol knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the...

Page 13: ...hant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pendant environ 90 secondes apr s l allumage de la veilleuse Rel ch...

Page 14: ...of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Tu...

Page 15: ...n d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournezlamanetteder glagedugaz lapositiond arr t OFF 6 Atte...

Page 16: ...only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 9 on page 7 Check burner orifice for stoppage and remove C...

Page 17: ...iring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24...

Page 18: ...r e w o L C 5 0 4 2 9 B L 2 2 1 1 5 d n a r B e t a l p e m a N 1 0 3 9 L 6 5 2 2 1 1 6 t e S g o L 1 0 2 6 L 9 6 1 1 1 1 7 s r e b m E g n i w o l G f o g a B 3 5 L 8 8 1 1 1 1 8 e n o t S c i n a c...

Page 19: ...5 L 4 7 1 1 0 7 5 L 4 7 1 5 3 e b u T t o l i P 1 0 6 5 L 4 7 1 1 0 6 5 L 4 7 1 6 3 e l b a C d n A e d o r t c e l E 1 0 8 5 L 4 7 1 1 0 8 5 L 4 7 1 7 3 e c i f i r O 1 0 0 8 J 0 6 2 1 0 2 5 L 9 1 2...

Page 20: ...nd also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 REPLACEMENT PARTS Model CDPF Shown see table o...

Reviews: